<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - with light source]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/with_light_source--2717/1/with light source.html]]></link><item>
<title><![CDATA[UTOCO Handheld Laser Detector with Tdlas for Natural Gas Distribution Pipeline]]></title><link><![CDATA[https://utoco.en.ec21.com/UTOCO_Handheld_Laser_Detector_with--12010082_12010092.html]]></link><description><![CDATA[sources, enhancing work efficiency and reducing labor demands.
The TDLAS sensor offers high sensitivity, rapid response, and exceptional selectivity, responding exclusively to methane and minimizing ]]></description><pubDate><![CDATA[20240926]]></pubDate></item>
<item>
<title><![CDATA[GF018A Clamp Type Multimeter Calibrator]]></title><link><![CDATA[https://gfuvegroup.en.ec21.com/GF018A_Clamp_Type_Multimeter_Calibrator--11546876_11999025.html]]></link><description><![CDATA[With 200A, 600A, 1000A calibration coil;
■ High precision AC/DC voltage source &amp; current source;
■ Because of light weight, this device is more suitable for field use;
■ With RS-232 interface, ]]></description><pubDate><![CDATA[20240905]]></pubDate></item>
<item>
<title><![CDATA[Isotech 4852 ADVANCED]]></title><link><![CDATA[https://nelsoncalib1.en.ec21.com/Isotech_4852_ADVANCED--11979684_11979688.html]]></link><description><![CDATA[sources to help you maximize your instruments&apos; potential.
Industries Served
Manufacturing
Aerospace
Automotive
Energy
Research and Development
Contact Us
For more information visit our website at www]]></description><pubDate><![CDATA[20240803]]></pubDate></item>
<item>
<title><![CDATA[IEC60695-11-4 UL94 Horizontal and Vertical Flame Test Apparatus]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC60695_11_4_UL94_Horizontal--11940578_11941787.html]]></link><description><![CDATA[source (methane or natural gas) to ignite the horizontal or vertical specimen for several times in a certain flame height and a certain flame angle, the fire hazard is evaluated by burning rate, afte]]></description><pubDate><![CDATA[20240524]]></pubDate></item>
<item>
<title><![CDATA[Awire Optical Fiber Hand-held Power Meter -50+26dBm SC FC ST Interchangerable WT840066 for FTTH]]></title><link><![CDATA[https://awirefiber.en.ec21.com/Awire_Optical_Fiber_Hand_held--11830737_11830789.html]]></link><description><![CDATA[Light Source, VFL, etc.
Fiber Optic Passive Components: Such WDMs, Attenuators, Adapters, Patch Cords, pigtails, PLC splitters, fiber tools, etc. 
Awire Fiber will go on with its efforts and is expec]]></description><pubDate><![CDATA[20240509]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[with a separate communicator.
Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instrumentsSource/simulate volts, mA, thermocouples, RTDs, frequency,]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[Automatic Image Measuring Device]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Automatic_Image_Measuring_Device--11683816_11853605.html]]></link><description><![CDATA[light source
Surface light and outline light: white LED, brightness continuously adjustable
Power Supply
220 V ± 10%, 50 Hz electrical equipment requires reliable grounding: the grounding resistance]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[Bruker Tracer 5i Handheld XRF Spectrometer]]></title><link><![CDATA[https://thexrfstore.en.ec21.com/Bruker_Tracer_5i_Handheld_XRF--11822199_11822200.html]]></link><description><![CDATA[with battery; 1.6 kg (3.6 lbs) without batteryPower: Li-Ion battery and charger; AC adapterExcitation source: Rhodium (Rh) thin window X-ray tube; X-ray generator 6-50 kV with 4.5-195 uA, maximum 4 W]]></description><pubDate><![CDATA[20230720]]></pubDate></item>
<item>
<title><![CDATA[High Performance FTIR Fourier Transform Infrared Spectrometer]]></title><link><![CDATA[https://gbpitester.en.ec21.com/High_Performance_FTIR_Fourier_Transform--11631034_11631045.html]]></link><description><![CDATA[Light sourceImported high strength air cooling infrared light sourceTransmittance accuracyBetter than 50%TInterferometerMichelson interferometer，with built-in automatic collimating optical systemCo]]></description><pubDate><![CDATA[20220901]]></pubDate></item>
<item>
<title><![CDATA[Automatic Kinematic Viscometer]]></title><link><![CDATA[https://precisionbe.en.ec21.com/Automatic_Kinematic_Viscometer--11718430_11856620.html]]></link><description><![CDATA[source. 
Temperature control accuracy ±0.02°C
4.Unit of work: 2 units
5.Timing accuracy: ±0.01S
6.Test accuracy: &lt;1%
7.Heating method: electric heater
8.Display: Color touch screen
9.Control metho]]></description><pubDate><![CDATA[20231019]]></pubDate></item>
<item>
<title><![CDATA[LM-79 Moving Detector Goniophotometer (Mirror Type C)]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/LM_79_Moving_Detector_Goniophotometer--11882688_11882689.html]]></link><description><![CDATA[can measure all types of lighting sources, LED, Plant Lighting or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[High Precision Rotation Luminaire Goniospectroradiometer]]></title><link><![CDATA[https://15317383997.en.ec21.com/High_Precision_Rotation_Luminaire_Goniospectroradiometer--11812738_11812746.html]]></link><description><![CDATA[with facility for rotating the light source. The LSG-1890BCCD/LSG-1800ACCD can do the spatial CCT test and the intensity distribution test. It is for industrial laboratory photometric data measuremen]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[CST-50 Impact Specimen U/V Notch Projector]]></title><link><![CDATA[https://wanchen123.en.ec21.com/CST_50_Impact_Specimen_U--11774583_11774608.html]]></link><description><![CDATA[table rotary range: 0°-360°
Amplification rate: 50*
Objective lens: 2.5* 
rojecting objective lens: 20*
Light source: DC12V 100W
Dimension : 510*220*600
Weight: 18KG
Power 
supply: 220V 50Hz 150W
]]></description><pubDate><![CDATA[20230529]]></pubDate></item>
<item>
<title><![CDATA[300W Xenon Light Source System Photocatalysis Photocatalytic Xenon Lamp CEL-PF300-T8]]></title><link><![CDATA[https://aulight2021.en.ec21.com/300W_Xenon_Light_Source_System--11446837_11446854.html]]></link><description><![CDATA[light, and the xenon light source has a spectrum similar to sunlight.
CEL-PF300 series xenon lamp system is a high-power full-band light source with continuous wavelength distribution and spectrum co]]></description><pubDate><![CDATA[20230614]]></pubDate></item>
<item>
<title><![CDATA[Sobek Metallographic Tool-Makers Microscope]]></title><link><![CDATA[https://sobek.en.ec21.com/Sobek_Metallographic_Tool_Makers_Microscope--10029761_10670633.html]]></link><description><![CDATA[with DIC is available also. 
*The lamp source adopts the international advanced LED lighting to minimize the thermal expansion error that caused by the use of halogen bulb in the past. 
*By using the]]></description><pubDate><![CDATA[20180228]]></pubDate></item>
<item>
<title><![CDATA[High Precision CCD Spectroradiometer]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/High_Precision_CCD_Spectroradiometer--9657760_11802779.html]]></link><description><![CDATA[sources in the visible region by feedback control of the radiant power emitted by individual LEDs. This LED optical spectrum analyzer will be used as a transfer standard for photometric, colorimetric]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[LVLP Linear DC Power Supply]]></title><link><![CDATA[https://idealtek.en.ec21.com/LVLP_Linear_DC_Power_Supply--9605857_9605884.html]]></link><description><![CDATA[Withstand short-circuit under start-up or any working modes, sound &amp; light alarm when output has short.
Over load protection: Auto-tripping when power supply or load has fault and output current exce]]></description><pubDate><![CDATA[20151002]]></pubDate></item>
<item>
<title><![CDATA[AS-2011 Micron Laser Particle Size Analyzer 0.1-500um]]></title><link><![CDATA[https://aimsizer.en.ec21.com/AS_2011_Micron_Laser_Particle--4628668_4628669.html]]></link><description><![CDATA[Light source:Semiconductor laser (635nm, 3mw, 25000hrs)
Scanning speed: 2000/sec
Test time:&lt; 1 minute, sample preparation not counted
Power supply:AC 220V&amp;plusmn;10% 50Hz or 60Hz,Power 80W
Computer i]]></description><pubDate><![CDATA[20100926]]></pubDate></item>
<item>
<title><![CDATA[Horizontal and Vertical Flammability Tester UL94 IEC 60695]]></title><link><![CDATA[https://fulfilling.en.ec21.com/Horizontal_and_Vertical_Flammability_Tester--5441143_9767620.html]]></link><description><![CDATA[TN1938 Horizontal and Vertical Flammability Tester 
INTRODUCTION 
1.Use the Bunsen burner with specified size and specific gas source (methane and 
propane),to burn samples(90 &amp;deg;and 0 &amp;deg;) with ]]></description><pubDate><![CDATA[20170530]]></pubDate></item>
<item>
<title><![CDATA[Characteristics of Water Quality COD Measuring Instrument]]></title><link><![CDATA[https://kobebean24.en.ec21.com/Characteristics_of_Water_Quality_COD--11076331_11855969.html]]></link><description><![CDATA[light source is longer with imported tungsten lamps;10. Curve correction, supporting automatic curve correction and automatic saving;11. Memory curve, 5 manufacturer curves, 195 extension curves, a t]]></description><pubDate><![CDATA[20231018]]></pubDate></item>
<item>
<title><![CDATA[Ponovo T1000 Primary Injection Test Set for Different Types of Relays]]></title><link><![CDATA[https://xiaxiaoming.en.ec21.com/Ponovo_T1000_Primary_Injection_Test--11744128_11737778.html]]></link><description><![CDATA[sources allow phase angle and frequency to be adjusted smoothly. This makes it possible to precisely test directional and frequency relay. 1000A is integrated with two current sources and thus can te]]></description><pubDate><![CDATA[20230609]]></pubDate></item>
<item>
<title><![CDATA[Refractometer RA-620 / RA-600]]></title><link><![CDATA[https://kyotokem.en.ec21.com/Refractometer_RA_620_RA_600--8755029_8755113.html]]></link><description><![CDATA[Light Source
LED Na-D Line (589.3nm)
Measuring Items
Refractive Index, Brix, Other Concentrations
Measuring Range
Refractive Index (nD)
1.32000 - 1.58000
1.3200 - 1.7000
Brix
0.00 ~ 100.00%
Accuracy ]]></description><pubDate><![CDATA[20140212]]></pubDate></item>
<item>
<title><![CDATA[CO/CO2/SO2/NO Analyzer]]></title><link><![CDATA[https://xajunengins.en.ec21.com/CO_CO2_SO2_NO_Analyzer--10893051_11403132.html]]></link><description><![CDATA[with other gas analyzer under same condition, 4 groups (max)
Application
1. Environmental monitor of atmosphere &amp; polluting source emission, etc.
2. Industrial control of petroleum &amp; chemical, etc.
3]]></description><pubDate><![CDATA[20210621]]></pubDate></item>
<item>
<title><![CDATA[Hot Sale Window Tint Meter WTM-1100 Light Transmission Meter]]></title><link><![CDATA[https://105landtek.en.ec21.com/Hot_Sale_Window_Tint_Meter--11797706_11797708.html]]></link><description><![CDATA[Window Tint Meter WTM-1100
Details:
Display:10mm LCD
Measurement Range:0 to 100% Light Transmission
Resolution:0.1
Accuracy:± 2 %
Sample Thickness:Less Than 18mm / 0.7inch
Light Source:LED
Measuring]]></description><pubDate><![CDATA[20231125]]></pubDate></item>
<item>
<title><![CDATA[INTEKE Suspension Type Color Assessment Cabinet CAC(6B)]]></title><link><![CDATA[https://inteke.en.ec21.com/INTEKE_Suspension_Type_Color_Assessment--3541795_10577551.html]]></link><description><![CDATA[sources)
2
2
2
6
1
2
115V/60Hz
Optional fittings: 45&amp;deg; normative stand. 
Features: 
&gt; Time running display of each light source. 
&gt; Auto conversion between light sources; Different spectrum with s]]></description><pubDate><![CDATA[20171107]]></pubDate></item>
<item>
<title><![CDATA[Programmable Anti-yellowing Resistance Corrosion Tester]]></title><link><![CDATA[https://annie0423.en.ec21.com/Programmable_Anti_yellowing_Resistance_Corrosion--9938796_9938804.html]]></link><description><![CDATA[light sources. A variety of industrial products can make the reliability test, and this product can simulate the product in the sun, rain, humidity and dew conditions, including damage caused by blea]]></description><pubDate><![CDATA[20160523]]></pubDate></item>

</channel>
</rss>