<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - working temperature 5 60]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/working_temperature_5_60--2717/1/working temperature 5 60.html]]></link><item>
<title><![CDATA[Fluke TI480 PRO Thermal Imaging Camera]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke_TI480_PRO_Thermal_Imaging--12045274_12045346.html]]></link><description><![CDATA[5 inch (landscape), 640 x 480 LCDRugged, ergonomic design for one-handed use: YesDigital zoom: 2x and 4xTemperature measurement
Temperature measurement range (not calibrated below -10 °C): ≤-20 °]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke TI480 PRO 60 Hz, 640 X 480 High-Performance IR Thermal Camera]]></title><link><![CDATA[https://aceinstuments.en.ec21.com/Fluke_TI480_PRO_60_Hz--11561118_11932301.html]]></link><description><![CDATA[5 inch (landscape) 640 x 480 LCD touchscreen
Rugged, ergonomic design for one-handed use
Thermal sensitivity (NETD): ? 0.05 �C at 30 �C target temp (50 mK)
Temperature measurement range (not cali]]></description><pubDate><![CDATA[20250129]]></pubDate></item>
<item>
<title><![CDATA[Fluke TIX580 Infrared Camera]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_TIX580_Infrared_Camera--11790575_11793442.html]]></link><description><![CDATA[5 micron/macro Temperature measurementTemperature measurement range (not calibrated below -10 °C)-20 °C to 1000 °C (-4 °F to 1832 °F)Accuracy±2 °C or 2% (at 25 °C nominal, whichever is greate]]></description><pubDate><![CDATA[20250109]]></pubDate></item>
<item>
<title><![CDATA[New Fluke TI480 PRO 60HZ Thermal Imager]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/New_Fluke_TI480_PRO_60HZ--11927627_11927630.html]]></link><description><![CDATA[50 mK (NETD)Temperature Range Max1832 FTemperature Range Min-14 FImage Frequency60 HzField of View34 x 24 DegreesScreen Size3.5 INIR/Overlay Fusion ImageYesVideo OutputYesFocusAdjustable and FixedLas]]></description><pubDate><![CDATA[20250104]]></pubDate></item>
<item>
<title><![CDATA[Laser Distance Measurer]]></title><link><![CDATA[https://holo1.en.ec21.com/Laser_Distance_Measurer--11942959_11942962.html]]></link><description><![CDATA[5~40M
0.05~60M
0.05~80M
0.05~100M
0.05~120M
Measurement Accuracy
±1.5mm
Laser Class
Ⅱ
Laser Diode
635nm , P＜1mW
Battery Life
＞10000 times
Working Temperature
-10℃～+50℃
Storage Temperatur]]></description><pubDate><![CDATA[20241206]]></pubDate></item>
<item>
<title><![CDATA[Dissolved Ozone Meter Intelligent Online Water Ozone Analyzer Tester Sanitizer Ozone]]></title><link><![CDATA[https://nobotech.en.ec21.com/Dissolved_Ozone_Meter_Intelligent_Online--11181496_11182362.html]]></link><description><![CDATA[Working conditionsenvironmental temperature of 0~60℃, relative humidity ≤90%◇Output load:&lt;750Ω(4-20mA)◇Working voltage: 220VAC10%,50/60Hz.◇Dimension :96x105×168 mm◇Hole size:92×92mm]]></description><pubDate><![CDATA[20240929]]></pubDate></item>
<item>
<title><![CDATA[UTOCO Handheld Laser Detector with Tdlas for Natural Gas Distribution Pipeline]]></title><link><![CDATA[https://utoco.en.ec21.com/UTOCO_Handheld_Laser_Detector_with--12010082_12010092.html]]></link><description><![CDATA[5ppm·mDetection range0~100000ppm·mDistance50 metersResponse timeT90 &lt; 0.1 secondWorking temperature-20ºC~50ºCStorage temperature-20ºC~60ºCHumidity&lt;99% RH (no condensation)Explosion-proof gradeE]]></description><pubDate><![CDATA[20240926]]></pubDate></item>
<item>
<title><![CDATA[NDJ-5S Digital Lab Rotational Viscometer Cosmetic Viscometer Manufacturer]]></title><link><![CDATA[https://zotaimachine.en.ec21.com/NDJ_5S_Digital_Lab_Rotational--11144324_11963587.html]]></link><description><![CDATA[Working power
110V / 60Hz or 220V / 50Hz
Dimensions
400 × 400 × 480(mm)
Summary:
The NDJ Series Digital Rotary Viscometer measures the viscosity of Newtonian liquid or non-Newtonian liquids. The rh]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[2 Axis 2 Frame POD Multiple Spectral Electro Optic Camera Sensor 4.5kg]]></title><link><![CDATA[https://leadir.en.ec21.com/2_Axis_2_Frame_POD--11958808_11958803.html]]></link><description><![CDATA[60mm
weight
≤ 
4.2kg
Voltage
Standard 24VDC,adaptable to 19-32VDC
Power consumption
Average power consumption&lt;35w,peak&lt;100w
Azimuth Axis working angle
Nx360°
Elevation Axis working angle
-110°~+3]]></description><pubDate><![CDATA[20240628]]></pubDate></item>
<item>
<title><![CDATA[High Low Temperature Low Air Pressure Test Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/High_Low_Temperature_Low_Air--11164019_11164150.html]]></link><description><![CDATA[550 mm
2050*900*1550 mm
3250*1150*1950 mm
3400*1450*1950 mm
Temperature Control mode
BTPC: Balanced temperature &amp; pressure control
Working environment temperature
+5…+35 ℃
Performance 
Temperatur]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[IEC61000-4-5 Lightning Surge Generator with 15KV Output Voltage]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC61000_4_5_Lightning_Surge--11944039_11944066.html]]></link><description><![CDATA[L-PE ,N-PE
Coupling device
18μF capacitance (L-N), 10Ω resistor+9μF capacitance (L-PE)
Working environment
Temperature:15°C－35°C humidity:10%－75%
Power supply
AC220±10％，50/60Hz 
]]></description><pubDate><![CDATA[20240528]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[54 does the work of several tools - sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. You’ll fall in love with the new improved graph]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[KRD11 Pneumatic Vertical Shock/Bump Test System Impact Testing Machine]]></title><link><![CDATA[https://creditcme.en.ec21.com/KRD11_Pneumatic_Vertical_Shock_Bump--11098426_11471888.html]]></link><description><![CDATA[working distance of 800 ~ 1000mm shall be
reserved around the equipment
Technical Specifications
Model
Parameters
KRD
11－5
KRD
11－15
KRD
11－25
KRD
11－50
KRD
11－100
KRD
11－200
KRD
11－400]]></description><pubDate><![CDATA[20240402]]></pubDate></item>
<item>
<title><![CDATA[Temperature Shock Chamber (Three-zone)]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/Temperature_Shock_Chamber_Three_zone--11853101_11853495.html]]></link><description><![CDATA[temperature zone
Pre-cooling temperature lower limit
-75℃
Cooling time
R.T～-70℃: 90min (approximately)
Working zone
Temperature
range
High
temperature:+60℃～+150℃;
Low temperature: -55℃]]></description><pubDate><![CDATA[20231013]]></pubDate></item>
<item>
<title><![CDATA[CDW-60 Impact Test Low Temperature Chamber / Environmental Chamber]]></title><link><![CDATA[https://astmtester123.en.ec21.com/CDW_60_Impact_Test_Low--9999940_10000040.html]]></link><description><![CDATA[temperature, to fully meet the temperature indicators of national standard GB/T229-2007, EN10045-2, E23-02A of the provisions.
3.The equipment is simple, convenient and efficient for working, which i]]></description><pubDate><![CDATA[20190815]]></pubDate></item>
<item>
<title><![CDATA[Low Temperature Meter / Impact Testing Machine]]></title><link><![CDATA[https://lgtester789.en.ec21.com/Low_Temperature_Meter_Impact_Testing--10000308_10000400.html]]></link><description><![CDATA[temperature, to fully meet the temperature indicators of national standard GB/T229-2007, EN10045-2, E23-02A of the provisions.
3.The equipment is simple, convenient and efficient for working, which i]]></description><pubDate><![CDATA[20190821]]></pubDate></item>
<item>
<title><![CDATA[Sobek Metallographic Tool-Makers Microscope]]></title><link><![CDATA[https://sobek.en.ec21.com/Sobek_Metallographic_Tool_Makers_Microscope--10029761_10670633.html]]></link><description><![CDATA[working distance: 4.0 mm
LWDPLAN 50X: (N.A)0.55, working distance: 7.5 mm
Optical system
CSIC infinity correction optical system
Power
220V&amp;plusmn;10% ，50Hz , 0.5KW
envirment requiry
temperature ra]]></description><pubDate><![CDATA[20180228]]></pubDate></item>
<item>
<title><![CDATA[100kW/200kW/500kW/800kW/1000kW/1200kW/2000kW AC Dummy Resistive Load Bank for Generator Load Test]]></title><link><![CDATA[https://rataloadbank.en.ec21.com/100kW_200kW_500kW_800kW_1000kW--11807078_11807097.html]]></link><description><![CDATA[Working mode(Duty cycle) : continuous work
Load protection : short circuit,over current,high temperature,fan fault protection,emergency stop
Work voltage : AC380V/50Hz,3 phase 4 wire
Cooling mode : f]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[Digital CM-230 Economic Conductivity Meter for Water Monitoring and Testing]]></title><link><![CDATA[https://chimaytech.en.ec21.com/Digital_CM_230_Economic_Conductivity--11544779_11544789.html]]></link><description><![CDATA[5℃ basis,automatic temperature compensation
Oper.Temp.: 0~50℃
Sensor:10cm-1
Display:3 1/2Bit LCD
Power: AC 110V±10% 50/60Hz; or AC 220V±10% 50/60Hz
Working environment: Ambient temperature:0~50]]></description><pubDate><![CDATA[20220318]]></pubDate></item>
<item>
<title><![CDATA[High Precision Spectroradiometer Integrating Sphere System]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/High_Precision_Spectroradiometer_Integrating_Sphere--9657760_11802275.html]]></link><description><![CDATA[500C) work with a IS-1.5MT Constant Temperature Integrating Sphere and TMP-8 Multiplex Temperature Tester can fully meet IES LM-82
High Precision LPCE-2(LMS-9000C) System Configuration (It is suitabl]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[China MIL-STD-810H Military Standard Dual Blowing Dust Sand Proof Resistance Test Chamber Machine]]></title><link><![CDATA[https://enviclonetestchamber.en.ec21.com/China_MIL_STD_810H_Military--11887764_11887766.html]]></link><description><![CDATA[600 x 600 x 7002000 x 4200 x 220045kW2. Specification3. PerformanceTemperature Range23°C~70°CTemperature Deviation≤ ±2°CHumidity＜ 30%R.HAir Velocity1.5 ~ 8.9 m/s (blown dust)18.0 ~ 29.0 m/s (]]></description><pubDate><![CDATA[20240114]]></pubDate></item>
<item>
<title><![CDATA[Flexible Rogowski Coils]]></title><link><![CDATA[https://xinghuodianzi.en.ec21.com/Flexible_Rogowski_Coils--11857606_11857607.html]]></link><description><![CDATA[± 1.5% maximumCoil Working voltage: 1000VRMS or 1000VDCCoil Dielectric Surge Withstand: 5kVRMS for 1 minuteOperating temperature: -20ºC to +60ºCLeads: Shielded cable, or as per customer need
]]></description><pubDate><![CDATA[20231031]]></pubDate></item>
<item>
<title><![CDATA[Low Temperature Dynamic Viscosity Tester]]></title><link><![CDATA[https://precisionbe.en.ec21.com/Low_Temperature_Dynamic_Viscosity_Tester--11718430_11856912.html]]></link><description><![CDATA[Temperature control range: -5℃ -10℃ -15℃ -20℃ -25℃ -30℃ -35℃
8. Temperature control accuracy: ±0.02℃
9. Working power supply: AC220,240
V 50,60Hz
10. Power of the whole machine: 1000]]></description><pubDate><![CDATA[20231020]]></pubDate></item>
<item>
<title><![CDATA[High Precision Spectroradiometer Integrating Sphere System]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/High_Precision_Spectroradiometer_Integrating_Sphere--11882688_11882693.html]]></link><description><![CDATA[500C) work with a IS-1.5MT Constant Temperature Integrating Sphere and TMP-8 Multiplex Temperature Tester can fully meet IES LM-82
High Precision LPCE-2(LMS-9000C) System Configuration (It is suitabl]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[Horizontal Type Valve Pressure Test Bench]]></title><link><![CDATA[https://valvegrindingmachine.en.ec21.com/Horizontal_Type_Valve_Pressure_Test--10886107_10886118.html]]></link><description><![CDATA[5Mpa(4500LB) Max
Nominal Voltage
Exchange 380V
Rated Power
8.5KW
Line Voltage
Exchange 220V/24V
Hydraulic oil
N46 hydraulic Oil(provide by user)
The oil temperature is Max 60 degrees centigrade ,
Min]]></description><pubDate><![CDATA[20220509]]></pubDate></item>
<item>
<title><![CDATA[Automatic Image Measuring Device]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Automatic_Image_Measuring_Device--11683816_11853605.html]]></link><description><![CDATA[5040
Stroke（mm）
500 *400*200
Overall dimension （mm）
825*1077*1280
Worktable （mm）
660*560
Overall weight (kg)
420
Glass load (kg)
20
Z-axis lifting distance
200MM
Working distance
90 mm
Me]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[Temperature Humidity Standard Environment Experiment Calibration Chamber Cabinet]]></title><link><![CDATA[https://tadt2023.en.ec21.com/Temperature_Humidity_Standard_Environment_Experiment--11689458_11689464.html]]></link><description><![CDATA[temperature and humidity are controlled by piecewise PID, fast and stable ,&quot; zero &quot;overshoot, fast and stable humidity from 40 RH to 60 RH only 15 minutes
* Fan speed regulation: inner cavity main ci]]></description><pubDate><![CDATA[20221209]]></pubDate></item>
<item>
<title><![CDATA[MDKS Wet Gas Flow Meter Gas Meter Test Bench]]></title><link><![CDATA[https://royreal.en.ec21.com/MDKS_Wet_Gas_Flow_Meter--11907986_11909896.html]]></link><description><![CDATA[5%，≤0.3%
Inspection table specification
G1.6 G2.5 G4（0.016m3/h～6m3/h）
Absolute Pressure Transmitter
（60～110）kPa
Temperature Test
(0～50)℃
Pressure Transmitter
(-100～100) kPa
Diff]]></description><pubDate><![CDATA[20240308]]></pubDate></item>
<item>
<title><![CDATA[Salt Spray Tester (SO2 Sulfur Dioxide]]></title><link><![CDATA[https://alibiota1431.en.ec21.com/Salt_Spray_Tester_SO2_Sulfur--11847960_11847970.html]]></link><description><![CDATA[working continuously.various models can meet different test requirements,such as Model STC-60 salt spray tester(110L),STC-90L salt spray chamber (270L),STC-120 salt spray chamber(500L),STC-160walk in]]></description><pubDate><![CDATA[20231120]]></pubDate></item>
<item>
<title><![CDATA[New Olympus BondMaster 600 Multimode Bond Tester]]></title><link><![CDATA[https://117714.en.ec21.com/New_Olympus_BondMaster_600_Multimode--11801594_11801602.html]]></link><description><![CDATA[60 Hz
Inputs and OutputsOne USB 2.0 peripheral port, one standard VGA analog output port, one 15-pin I/O port (male) with analog output, 3 alarm outputs.Environmental ConditionsOperating Temperature]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[High Purity Gas Generator, Hydrogen Generator, Nitrogen Generator]]></title><link><![CDATA[https://huishiyiqi2024.en.ec21.com/High_Purity_Gas_Generator_Hydrogen--11907876_11909357.html]]></link><description><![CDATA[500
Output pressure (MPa) 0.4 (factory set at 0.3) adjustable
Working power supply 110/220V ± 10%; 50/60Hz ± 5%
Maximum power (W) 200
Environmental conditions and temperature: 10-40 ℃; Relative h]]></description><pubDate><![CDATA[20240307]]></pubDate></item>
<item>
<title><![CDATA[Dustproof Testing Machine | Dust Proof Chamber]]></title><link><![CDATA[https://15317383997.en.ec21.com/Dustproof_Testing_Machine_Dust_Proof--11812738_11858081.html]]></link><description><![CDATA[5X and IP6X dustproof test.
Product Model:
Model NumberWorking Room Size (mm)RemarkWorking Power SupplySC-500800*800*800Single door structure220-240V/50Hz Single Phase (60Hz is optional)SC-0101000*10]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[Photocatalytic Xenon Lamp Light Source Photocatalysis Photocatalytic Visible Light UV Light]]></title><link><![CDATA[https://aulight2021.en.ec21.com/Photocatalytic_Xenon_Lamp_Light_Source--11446837_11446862.html]]></link><description><![CDATA[Working DC 14V）
Working Current (Amps DC)
21A（10A~22A）
Total Output light Power
50W
Bulb Life（Hours）
&gt;1000H 
Output stability
±1%
Temperature Control System
The light source system adopts ]]></description><pubDate><![CDATA[20240104]]></pubDate></item>
<item>
<title><![CDATA[Cold and Hot Shock Test Box / Cold and Hot Impact Tester]]></title><link><![CDATA[https://lituotest.en.ec21.com/Cold_and_Hot_Shock_Test--11372570_11372577.html]]></link><description><![CDATA[550mm3. Temperature range :(-45ºC, -55ºC, -65ºC, -70ºC) ~ 150ºC4. Temperature range of high temperature zone: +60ºC ~ +150ºC5. Temperature range of test area: +110ºC ~ -70ºC6. Low temperatur]]></description><pubDate><![CDATA[20210424]]></pubDate></item>
<item>
<title><![CDATA[Computer Control YFTD300 Safety Valve Test Bench for Safety Valve Pressure Calibration and Seal Test]]></title><link><![CDATA[https://king3834656.en.ec21.com/Computer_Control_YFTD300_Safety_Valve--11745449_11747422.html]]></link><description><![CDATA[working, system returns to normal state to effectively reduce oil temperature, prolonging life of the test bench and saving energy. 7. hydraulic clamping has safety interlock with air pressure discha]]></description><pubDate><![CDATA[20230330]]></pubDate></item>
<item>
<title><![CDATA[Dissolution Tester Device]]></title><link><![CDATA[https://jiahang1.en.ec21.com/Dissolution_Tester_Device--11600339_11853671.html]]></link><description><![CDATA[Working noise: &lt;60db• Environmental conditions: ambient temperature 5-37 ℃, relative humidity ≤ 80%• Safety performance: in line with national industry standards, with self-inspection and aut]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[IEC61000-4-5 Lightning Surge Generator]]></title><link><![CDATA[https://pegogroup.en.ec21.com/IEC61000_4_5_Lightning_Surge--11421920_11421956.html]]></link><description><![CDATA[50/60Hz
DC：300V，10A（16AMax）
EUT power supply
AC110-220V±10％，50/60Hz
Coupling mode
L-N,L-PE，N-PE，L+N-PE
Working environment
Temperature:15°C－35°C humidity:0%－75%
Power supply
AC]]></description><pubDate><![CDATA[20210729]]></pubDate></item>
<item>
<title><![CDATA[ACP Electrical Current Transformer Test, CT/PT Analyzer]]></title><link><![CDATA[https://aijiezn.en.ec21.com/ACP_Electrical_Current_Transformer_Test--3533367_11343743.html]]></link><description><![CDATA[Temperature
measurement
-50~100
Celsius degree, error&lt;3 Celsius degree
15
CT
Secondary burden
Range 0-160ohm (automatically
change range in 2ohm/ 20ohm/80ohm/160ohm)
Error&lt;0.2%RDG+0.02%FS 
Maximum
re]]></description><pubDate><![CDATA[20210224]]></pubDate></item>
<item>
<title><![CDATA[WASP-XM-R-SF6 Pump-priming Portable SF6 Gas Detector]]></title><link><![CDATA[https://mary00882009.en.ec21.com/WASP_XM_R_SF6_Pump--4088884_4088885.html]]></link><description><![CDATA[Temperature
-40 ℃ - 70 ℃
Relative Humidity
15% - 95%, non-condensing
Storage Temperature
-20 ℃ - 60 ℃
Storage humidity
&amp;le; 90%, no condensation
Sensor life
1 year
Continuous work hours
30 ho]]></description><pubDate><![CDATA[20170411]]></pubDate></item>
<item>
<title><![CDATA[CDW-80T  Low Temperature Impact Testing Meter]]></title><link><![CDATA[https://lgcs201088.en.ec21.com/CDW_80T_Low_Temperature_Impact--6692154_6692888.html]]></link><description><![CDATA[5, ISO148, ISO83 and other stipulated specifications related in the standard of temperature control index of the provisions. The equipment is simple, convenient and efficient for working, which is th]]></description><pubDate><![CDATA[20211028]]></pubDate></item>
<item>
<title><![CDATA[Hybrid Karl Fischer Moisture Titrator MKH-700]]></title><link><![CDATA[https://kyotokem.en.ec21.com/Hybrid_Karl_Fischer_Moisture_Titrator--8755027_8755067.html]]></link><description><![CDATA[56 colors 800 x 600 dots
Language
English / Japanese
Ambient conditions
Temperature
5 - 35&amp;deg;C
Humidity
85%RH or below (no condensation)
Power supply
Measuring unit
DC24V 5A (Main unit)
AC100-240V ]]></description><pubDate><![CDATA[20140212]]></pubDate></item>
<item>
<title><![CDATA[Digit LED Tube Voltage Current Power Meter Display HN-24SX]]></title><link><![CDATA[https://aoyijenny.en.ec21.com/Digit_LED_Tube_Voltage_Current--8875633_8878842.html]]></link><description><![CDATA[Precision: ±0.5% ±1Word
Working power supply: AC220V(85%～110%) 50/60Hz （ Voltage can be customized） 
Power Loss: &lt;3.5W
Environment temperature: 0℃～+40℃
Relative Humidity: &lt;85%]]></description><pubDate><![CDATA[20210619]]></pubDate></item>
<item>
<title><![CDATA[VSM Vibrating Sample Magnetometer M-H Curve Hysteresis Graph Test System Magnetic Properties]]></title><link><![CDATA[https://jackietsui.en.ec21.com/VSM_Vibrating_Sample_Magnetometer_M--8508233_11795131.html]]></link><description><![CDATA[work superior ±1%.
5. Temperature range: from -196℃ to 900℃.
6. The magnetic Pole pitch for a fixed spacing is 40 mm, and the pole face diameter is 60 mm.
7. Magnetic field: supplied by the elec]]></description><pubDate><![CDATA[20230522]]></pubDate></item>

</channel>