<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - secondary coil]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/secondary_coil--0924/1/secondary coil.html]]></link><item>
<title><![CDATA[50kVA Distribution Transformer]]></title><link><![CDATA[https://zcelectric888.en.ec21.com/50kVA_Distribution_Transformer--11987763_11987825.html]]></link><description><![CDATA[It is a device that utilizes the principle of electromagnetic induction to alter alternating current (AC) voltage. Its main components are the primary coil, secondary coil, and iron core (magnetic co]]></description><pubDate><![CDATA[20240819]]></pubDate></item>
<item>
<title><![CDATA[Current Transformer]]></title><link><![CDATA[https://maikecn666.en.ec21.com/Current_Transformer--11924175_11930922.html]]></link><description><![CDATA[secondary circuit is always closed, so the impedance of the series coil of the measuring instrument and the protection circuit is very small, and the working state of the current transformer is close]]></description><pubDate><![CDATA[20240429]]></pubDate></item>
<item>
<title><![CDATA[Rogowski Coil with BNC Connector for Oscilloscope]]></title><link><![CDATA[https://xinghuodianzi.en.ec21.com/Rogowski_Coil_with_BNC_Connector--11857606_11860939.html]]></link><description><![CDATA[secondary signal outputs) is avoidedKey specifications Input current range:0-10000AOutput :Flexible Rogowski coils 0.333Vac,100mV/per 1000A, 0-5VacBandwidth :1Hz-1MHzAccuracy :≤±1%Response time :&lt;]]></description><pubDate><![CDATA[20231031]]></pubDate></item>
<item>
<title><![CDATA[Three Phase Industrial Oil Transformer]]></title><link><![CDATA[https://yuelong1.en.ec21.com/Three_Phase_Industrial_Oil_Transformer--11601815_11870956.html]]></link><description><![CDATA[secondary windings wound on one core and the shell-type transformer that combines three 1-phase transformers. In core-type three-phase transformers, the core has three limbs within the same plane.
To]]></description><pubDate><![CDATA[20231128]]></pubDate></item>
<item>
<title><![CDATA[VPI Dry type Transformer]]></title><link><![CDATA[https://dbeco.en.ec21.com/VPI_Dry_type_Transformer--1366674_1366794.html]]></link><description><![CDATA[VPI(Vacuum Pressure Impregnation)
The coils shall be dried at atmospheric pressure in an over through which hot air is continuously circulated.
The totally dried ciiles shall be vacuum pressure impar]]></description><pubDate><![CDATA[20160817]]></pubDate></item>
<item>
<title><![CDATA[Grey Color 3000A Clamp On Ct AC Current Probe for Cable Fault Tester]]></title><link><![CDATA[https://gfuve0123.en.ec21.com/Grey_Color_3000A_Clamp_On--10658139_10659333.html]]></link><description><![CDATA[Secondary Current
Coil Ratio
Burden Resistance
Accuracy
Q125B-500
500A
600A
5A
100:1
2.5VA
0.5%
Q125B-600
600A
720A
5A
120:1
2.5VA
0.5%
Q125B-800
800A
960A
5A
160:1
2.5VA
0.5%
Q125B-1000
1000A
1200A
]]></description><pubDate><![CDATA[20180509]]></pubDate></item>