<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - pressure source]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/pressure_source--2053/1/pressure source.html]]></link><item>
<title><![CDATA[SS-2BV-8FFL Coplanar Two-valve Group]]></title><link><![CDATA[https://baoyi123456.en.ec21.com/SS_2BV_8FFL_Coplanar_Two--12048718_12048725.html]]></link><description><![CDATA[source: Transmitter connector
▲Input and export thread: 1/2NPT or flange
▲Applicable media: corrosive and non-corrosive media such as oil, water, and gas
▲Nominal pressure: 20.0Mpa, 40.0Mpa,
]]></description><pubDate><![CDATA[20250313]]></pubDate></item>
<item>
<title><![CDATA[Pneumatic Cage-Guided Regulating Globe Valve]]></title><link><![CDATA[https://cnzpv.en.ec21.com/Pneumatic_Cage_Guided_Regulating_Globe--12025004_12025009.html]]></link><description><![CDATA[source②Electric control valve : electricity as the source③Hydraulic control valve: liquid medium (such as oil, etc.) pressure as the source○By Adjustment Mode :① Regulating type② Cut-off ty]]></description><pubDate><![CDATA[20241121]]></pubDate></item>
<item>
<title><![CDATA[Self-Actuated Regulating Valves Self-Operated Control Valves for Pipeline Pressure Adjusting]]></title><link><![CDATA[https://zhipengvalve.en.ec21.com/Self_Actuated_Regulating_Valves_Self--11948701_11949223.html]]></link><description><![CDATA[pressure regulating valve is operates autonomously, using the energy of the controlled medium without relying on external power sources. Its key advantage lies in its ability to function effectively ]]></description><pubDate><![CDATA[20240608]]></pubDate></item>
<item>
<title><![CDATA[Dynamic Flow Control Valve]]></title><link><![CDATA[https://985980671.en.ec21.com/Dynamic_Flow_Control_Valve--11034618_7766650.html]]></link><description><![CDATA[pressure fluctuation of the system and keep the flow unchanged.
2.Overcome the uneven heating and cooling of the system and improve the quality of heating (cooling).
3.Thoroughly resolve the contradi]]></description><pubDate><![CDATA[20230525]]></pubDate></item>
<item>
<title><![CDATA[304SS. 316 SS.Pneumatic Actuator]]></title><link><![CDATA[https://judyzhaoveson.en.ec21.com/304SS._316_SS.Pneumatic_Actuator--9782389_9782406.html]]></link><description><![CDATA[1million time or 1year
Model Range: AT052 - AT270
Double Acting&amp;Spring Return
Air Source Pressure Range: 0.3MPa -0.8MPa 
Connection standard: ISO5211/VDI/VDE3845
]]></description><pubDate><![CDATA[20151208]]></pubDate></item>
<item>
<title><![CDATA[Deflagration Flame Arrester]]></title><link><![CDATA[https://finekay.en.ec21.com/Deflagration_Flame_Arrester--8590311_8591193.html]]></link><description><![CDATA[source is strictly controlled. While the distance goes over n that is the ratio of L/D regulated (that is, L is larger than n-times of pipe diameter D), the explosion-proof back-fire relief valve mus]]></description><pubDate><![CDATA[20140606]]></pubDate></item>
<item>
<title><![CDATA[Cryogenic Ball Valves]]></title><link><![CDATA[https://mfrsvalve.en.ec21.com/Cryogenic_Ball_Valves--11116526_11116532.html]]></link><description><![CDATA[source of clean energy. VIZA develops its cryogenic floating (Series FY) and Trunnion mounted (Series TY) ball valve accordingly.
Standards
ASME B16.34, ASME B16.5, API 6D, BS EN ISO 17292, BS 6364, ]]></description><pubDate><![CDATA[20200425]]></pubDate></item>
<item>
<title><![CDATA[Pneumatic Pressure Control Valve]]></title><link><![CDATA[https://supconvalve.en.ec21.com/Pneumatic_Pressure_Control_Valve--11032707_11892346.html]]></link><description><![CDATA[pressure at the set value while preventing overloading of the equipment. Unloading valves are designed for economic pressure control in accumulator operating circuits and are used as a power source f]]></description><pubDate><![CDATA[20240123]]></pubDate></item>
<item>
<title><![CDATA[Industrial Hydraulic Solenoid Valve Two Position Six Way 12V 24V DC]]></title><link><![CDATA[https://hydraulicsvalve.en.ec21.com/Industrial_Hydraulic_Solenoid_Valve_Two--11885558_11885559.html]]></link><description><![CDATA[PRODUCT DESCRIPTIONProduct Pictures: KL7102107ER27ER two position six way solenoid valve with 12V 24V DC coil and steel valve body Description :Techanical reference:Rated pressure: 25MPaMaximum peak ]]></description><pubDate><![CDATA[20240109]]></pubDate></item>
<item>
<title><![CDATA[YT-1000 ROTORK Ytc Smart Positioner Electric Actuator with Control Valve]]></title><link><![CDATA[https://actuatorpositioner.en.ec21.com/YT_1000_ROTORK_Ytc_Smart--11881437_11881438.html]]></link><description><![CDATA[source pipeline can be connected to realize the adjustment control. Technical Parameter:ModelItemWOOL (LinearType) 1000R (RotaryType)Single acting Double actingInput signal, resistance4~20mA.DC250Q+1]]></description><pubDate><![CDATA[20231229]]></pubDate></item>
<item>
<title><![CDATA[High Performance Butterfly Valve]]></title><link><![CDATA[https://haiyingvalve.en.ec21.com/High_Performance_Butterfly_Valve--11725077_11725079.html]]></link><description><![CDATA[pressure test. The flow characteristics of such valves are approximately equal to the percent.
Advantage:
1. Reasonable design, compact structure, easy installation and disassembly, easy to repair.
2]]></description><pubDate><![CDATA[20230210]]></pubDate></item>
<item>
<title><![CDATA[Double-door Bottom Valve]]></title><link><![CDATA[https://jayopetromachinery.en.ec21.com/Double_door_Bottom_Valve--11684858_11861779.html]]></link><description><![CDATA[source, and has the function of only entering and exiting. There are many water inlets and reinforcements on the valve cover. Ribs, which are not easy to block, are mainly used in pumping pipelines. ]]></description><pubDate><![CDATA[20231102]]></pubDate></item>
<item>
<title><![CDATA[HNOR Pneumatic Actuator]]></title><link><![CDATA[https://szhtx88.en.ec21.com/HNOR_Pneumatic_Actuator--10964854_10964951.html]]></link><description><![CDATA[pressure reducing valve, TOPWOR travel switch, VASLCO air control valve, VASLCO air source amplifier, VASLCO air lock valve throttle valve, quick exhaust valve, etc.)
Technical specifications
Rated t]]></description><pubDate><![CDATA[20231214]]></pubDate></item>
<item>
<title><![CDATA[Stainless Steel Hose Union Bibcock Bib Tap Outside Taps]]></title><link><![CDATA[https://bibcockvalve.en.ec21.com/Stainless_Steel_Hose_Union_Bibcock--11866754_11866755.html]]></link><description><![CDATA[Product DescriptionHose Union Bib Tap,Outside Taps,
Detail About Bibcock Valve Outside Taps,HBC-55802
The bibcock is connected to a water source on one end and the other end is an outlet
Finising:Pol]]></description><pubDate><![CDATA[20231115]]></pubDate></item>
<item>
<title><![CDATA[Direct Acting Sequence Valve]]></title><link><![CDATA[https://valzoom.en.ec21.com/Direct_Acting_Sequence_Valve--11836037_11836040.html]]></link><description><![CDATA[pressurized hydraulic fluid from a pump or another power source. It also has one or more outlet ports that are connected to the hydraulic actuators or cylinders.
02
Set Pressure
The valve is designed]]></description><pubDate><![CDATA[20230821]]></pubDate></item>
<item>
<title><![CDATA[D342X Double Eccentric Butterfly Valve]]></title><link><![CDATA[https://disaivalve.en.ec21.com/D342X_Double_Eccentric_Butterfly_Valve--11865326_11865328.html]]></link><description><![CDATA[source engineering, environmental facility construction, and various other sectors. Particularly well-suited for water pipelines, this double eccentric butterfly valve serves as both a regulation and]]></description><pubDate><![CDATA[20231111]]></pubDate></item>
<item>
<title><![CDATA[High Torque Pneumatic Actuator]]></title><link><![CDATA[https://juhang1.en.ec21.com/High_Torque_Pneumatic_Actuator--11601080_11853726.html]]></link><description><![CDATA[Pressure:3 - 8 barCylinder body material:Aluminum alloy (surface coating: hard anodized)End cover material:Die-casting aluminum alloy (surface coating: powder spraying)Air source control:Through filt]]></description><pubDate><![CDATA[20231012]]></pubDate></item>

</channel>
</rss>