<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - thermocouple sensors]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/thermocouple sensors.html]]></link><item>
<title><![CDATA[J Type Thermocouple Temperature Sensor]]></title><link><![CDATA[https://chengdusand.en.ec21.com/J_Type_Thermocouple_Temperature_Sensor--11046184_11046219.html]]></link><description><![CDATA[sensor;
Electrical Connectrion is direct cable connection 
Probe thread size is 1/2&quot;-20UNF; 
Conical probe depth is 15mm; 
Rigid stem length is 150mm,J type thermocouple. 
Sample 2 :MT3012-M18-15-150]]></description><pubDate><![CDATA[20191226]]></pubDate></item>
<item>
<title><![CDATA[10000L(10T) Beer Brewing Equipment]]></title><link><![CDATA[https://hgbeerequipmemt.en.ec21.com/10000L_10T_Beer_Brewing_Equipment--12028333_12030271.html]]></link><description><![CDATA[sensors;Integrated pump system;CIP system: separated CIP for individual tanks to prevent cross product interference;Master brew interface control system (touch screen control panel),Staircases and pl]]></description><pubDate><![CDATA[20260304]]></pubDate></item>
<item>
<title><![CDATA[Custom Sizes  High-Temperature FEP Heat Shrink Tubing for Moisture Sealing  Electrical Power System]]></title><link><![CDATA[https://keyusce.en.ec21.com/Custom_Sizes_High_Temperature_FEP--12059644_12060503.html]]></link><description><![CDATA[thermocouple from the high temperature oil environments.
2, Provide machinery protection for all kinds of metal wire. For example: protect, insulate and reinforce the end of the wire, wiring, and ter]]></description><pubDate><![CDATA[20260202]]></pubDate></item>
<item>
<title><![CDATA[Low-Power, Sigma-Delta ADC with PGA and Reference SSP1220]]></title><link><![CDATA[https://siproinanna.en.ec21.com/Low_Power_Sigma_Delta_ADC--12033266_12034321.html]]></link><description><![CDATA[sensor signals, such as resistance temperature detectors (RTDs), thermocouples, thermistors, and bridge sensors. Power consumption is as low as 120 µA 3.3V when operating in duty cycle mode with the]]></description><pubDate><![CDATA[20250102]]></pubDate></item>
<item>
<title><![CDATA[YH Series Dry Well Furnace]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH_Series_Dry_Well_Furnace--12022540_12022547.html]]></link><description><![CDATA[Product Features
◆ Double-way high-precision DC current, voltage, resistance signal and thermocouple, thermalresistance temperature measurement;
◆ 6-bit digital display, resolution of 0.001℃, l]]></description><pubDate><![CDATA[20241106]]></pubDate></item>
<item>
<title><![CDATA[ABB TTF200 and TTF300 Model Temperature Transmitter]]></title><link><![CDATA[https://miawang0812.en.ec21.com/ABB_TTF200_and_TTF300_Model--11988808_11988937.html]]></link><description><![CDATA[Sensor Input
Resistance thermometers, resistance-type remote sensors (0 to 5000 Ohm)
Thermocouples, voltages, mV-voltages (–125 to 1100 mV)
Pt100, two-wire, three-wire, four-wire, thermocouple with]]></description><pubDate><![CDATA[20241025]]></pubDate></item>
<item>
<title><![CDATA[Vacuum Brazing Furnace]]></title><link><![CDATA[https://und24.en.ec21.com/Vacuum_Brazing_Furnace--12009016_12009027.html]]></link><description><![CDATA[thermocouples to measure the temperature in the furnace at any time and understand the temperature uniformity.
4.4 The furnace control interface is a touch screen control system. Through communicatio]]></description><pubDate><![CDATA[20240924]]></pubDate></item>
<item>
<title><![CDATA[New and Good Price Rosemount 644 Temperature Transmitter]]></title><link><![CDATA[https://yaorendetuzi.en.ec21.com/New_and_Good_Price_Rosemount--12006567_12009158.html]]></link><description><![CDATA[the field without tools. For diverse application requirements, this transmitter includes diagnostic capabilities, such as Hot Backup™ capability, sensor drift alert and thermocouple degradation.]]></description><pubDate><![CDATA[20240924]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Multifunction Process Calibrator]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/Fluke_754_Documenting_Multifunction_Process--11927627_11927628.html]]></link><description><![CDATA[Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibr]]></description><pubDate><![CDATA[20240921]]></pubDate></item>
<item>
<title><![CDATA[RTM1102 Dual-Channel Thermocouple Thermometer with 0.01 Resolution]]></title><link><![CDATA[https://realltech2019.en.ec21.com/RTM1102_Dual_Channel_Thermocouple_Thermometer--11280722_11614777.html]]></link><description><![CDATA[Thermocouple Thermometer RTM-1102
1.Introduction:
RTM1102 is a high-precision of dual-channel digital thermocouple thermometer, which uses thermocouples as sensors to measure temperature signals, can]]></description><pubDate><![CDATA[20240915]]></pubDate></item>
<item>
<title><![CDATA[Megger BAKER DX15A RLC PD]]></title><link><![CDATA[https://nelsoncalib1.en.ec21.com/Megger_BAKER_DX15A_RLC_PD--11979684_11979685.html]]></link><description><![CDATA[sensors, and manometers
Recorders/Data Loggers: For temperature, humidity, and pressure
Scales and Balances: Precision balances, analytical scales, and industrial scales
Surface Testers: Roughness te]]></description><pubDate><![CDATA[20240803]]></pubDate></item>
<item>
<title><![CDATA[LoRa Temperature Sensor]]></title><link><![CDATA[https://nmgdmdz.en.ec21.com/LoRa_Temperature_Sensor--11973258_11973264.html]]></link><description><![CDATA[LoRa temperature sensor/LoRaWAN platinum thermal resistor/fixed thread thermocouple/temperature control/measurement battery power supply 9000mA or external power supply 470～510MHz (modifiable frequ]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[UNI-T UT805A+ True RMS Digital Multimeter Auto-range Dual-display]]></title><link><![CDATA[https://phonefix11.en.ec21.com/UNI_T_UT805A_True_RMS--11948200_11962103.html]]></link><description><![CDATA[sensor measurement built-in thermocouple cold junction compensation.
3. 1Gb flash memory storage which can support up to 10k data recall suit for production QA, phone repair, research, and education.]]></description><pubDate><![CDATA[20240703]]></pubDate></item>
<item>
<title><![CDATA[Packaging Machine]]></title><link><![CDATA[https://goleadmachine.en.ec21.com/Packaging_Machine--11905532_11941914.html]]></link><description><![CDATA[Thermocouple, a sensor for measuring temperature; Speed Controller, for adjusting machine speed; Photoelectric Switch, a sensor that uses light; Pelletizer Knife, for cutting in the pelletizing proce]]></description><pubDate><![CDATA[20240524]]></pubDate></item>
<item>
<title><![CDATA[IEC60695-11-5 Flammability Tester Needle Flame Tester with Button Operation]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC60695_11_5_Flammability_Tester--11940578_11941779.html]]></link><description><![CDATA[Thermocouple
Φ0.5mm K type thermocouple (The insulating sleeve heat resist to 1100 ℃)
Temperature sensor
Copper with Φ4mm and 0.58±0.1g weight, equip with K type thermocouple
Thermal radiation b]]></description><pubDate><![CDATA[20240524]]></pubDate></item>
<item>
<title><![CDATA[AccuThermo AW 610M Rapid Thermal Annealing]]></title><link><![CDATA[https://allwin21.en.ec21.com/AccuThermo_AW_610M_Rapid_Thermal--9759759_9763382.html]]></link><description><![CDATA[thermocouple (150-840C) and Non-Contact Patented ERP pyrometer (Option,400-1250C) . 0-0.25 second quick response for repeatability and precise control! Typical processes are 400-600C for alloy, 700-9]]></description><pubDate><![CDATA[20240514]]></pubDate></item>
<item>
<title><![CDATA[ABB Electrical Spare Parts]]></title><link><![CDATA[https://jiangstar.en.ec21.com/ABB_Electrical_Spare_Parts--9022887_9022932.html]]></link><description><![CDATA[Thermocouple inputs-type B, C, E, J, K, L, N 
200-PSMG 492898801 Power Supply Module 
200-RANN 492852901 Rack Adaptor Board 
200RB300002C Micro-Scan 200 Indicating Process Controller 
200-TB3T 490176]]></description><pubDate><![CDATA[20240418]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[thermocouples, frequency, and ohms to test sensors, transmitters and other instrumentsSource/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmittersPower tran]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[Signal SPD]]></title><link><![CDATA[https://chenzhu.en.ec21.com/Signal_SPD--11729194_11729196.html]]></link><description><![CDATA[sensors, transmitters, flow meters, solenoid valves, thermocouples, thermal resistance, devices with RS485 or RS232 interface and for I/O interfaces such as Al, AO, Dl, DO, Tl, Pl in PLC, DCS, FGS, E]]></description><pubDate><![CDATA[20230217]]></pubDate></item>
<item>
<title><![CDATA[GGA-70-1 O2 Flue Gas Analyzer]]></title><link><![CDATA[https://dxgltd.en.ec21.com/GGA_70_1_O2_Flue--11885117_11885679.html]]></link><description><![CDATA[thermocouple for excellent linearity betweentemperature and EMFMaintains measurement accuracy through periodic automaticself-check cyclesUtilizes an IC with built-in Cold Junction Compensation (CJC)f]]></description><pubDate><![CDATA[20240109]]></pubDate></item>
<item>
<title><![CDATA[35 To 600 Deg C Surface Sensor Temperature Calibration Hot Plate]]></title><link><![CDATA[https://tadt2023.en.ec21.com/35_To_600_Deg_C--11689040_11689586.html]]></link><description><![CDATA[sensors of various sizes and types, such as thermistors, film sensors, surface resistance thermometers, ribbon sensors, surface thermocouples, and more. The product consists of a controller and a hea]]></description><pubDate><![CDATA[20221209]]></pubDate></item>
<item>
<title><![CDATA[HI-Q Digital Air Flow Calibrator D-AFC]]></title><link><![CDATA[https://coastaltrading2005.en.ec21.com/HI_Q_Digital_Air_Flow--11837200_11837251.html]]></link><description><![CDATA[sensor, thermocouple, precision machined venturi tube and differential pressure sensor, HI-Q’s D-AFC- Series microprocessor based air flow calibrators are used to measure, record, &amp; display instant]]></description><pubDate><![CDATA[20230823]]></pubDate></item>
<item>
<title><![CDATA[China Cheap Bga Rework Station]]></title><link><![CDATA[https://rogerzhao2023.en.ec21.com/China_Cheap_Bga_Rework_Station--11842069_11842072.html]]></link><description><![CDATA[thermocouple,closed loop control,independent heatingTemperature accuracy±2℃PCB sizeMax 420*400 mm,Min 22*22 mmWorkbench fine-tune±15 mm forward/backward,±15 mm right/leftBGA chip2*2 - 80*80 mmMi]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[Industrial Induction Heater for Sale]]></title><link><![CDATA[https://tyinduction.en.ec21.com/Industrial_Induction_Heater_for_Sale--11686230_11822644.html]]></link><description><![CDATA[sensors, such as thermocouples or infrared cameras, are used to measure the temperature of the workpiece or surrounding environment. The control system can adjust the power or other parameters based ]]></description><pubDate><![CDATA[20240314]]></pubDate></item>
<item>
<title><![CDATA[Touch Screen Hot Runner Controller]]></title><link><![CDATA[https://tinko.en.ec21.com/Touch_Screen_Hot_Runner_Controller--11813328_11872933.html]]></link><description><![CDATA[thermocouple sensor transmits the electrical signal to the control card and converts it into a temperature value. Compared with the set target value, the hot runner controller determines the heater o]]></description><pubDate><![CDATA[20231204]]></pubDate></item>
<item>
<title><![CDATA[Ad595adz]]></title><link><![CDATA[https://thomasli.en.ec21.com/Ad595adz--11892242_11892264.html]]></link><description><![CDATA[thermocouple cold-junction compensation, ensuring precise and reliable temperature readings. With its wide temperature range and low output impedance, it facilitates straightforward interfacing with ]]></description><pubDate><![CDATA[20240123]]></pubDate></item>
<item>
<title><![CDATA[DM9600 Precision Manometer]]></title><link><![CDATA[https://mrulab.en.ec21.com/DM9600_Precision_Manometer--11523326_11535382.html]]></link><description><![CDATA[sensor
- 2 separate K-type thermocouple sockets for standard NiCrNi thermocouples
- 2,8&quot; touch, colour display
- Fibreglass reinforced enclosure with integrated fixing magnets
- Infrared printing int]]></description><pubDate><![CDATA[20220222]]></pubDate></item>
<item>
<title><![CDATA[FF/PA Protocal Smart Temperature Transmitter Instrument]]></title><link><![CDATA[https://microcyber2003.en.ec21.com/FF_PA_Protocal_Smart_Temperature--11077275_11077818.html]]></link><description><![CDATA[sensor input. It applied to a variety of thermal resistance and thermocouple sensors and has wide range. Each channel support individually configure the sensor type and two-wire system and three-wire]]></description><pubDate><![CDATA[20200312]]></pubDate></item>
<item>
<title><![CDATA[High Pressure Processing - HPP (Hippo)]]></title><link><![CDATA[https://ilshinauto.en.ec21.com/High_Pressure_Processing_HPP_Hippo--3722572_8934869.html]]></link><description><![CDATA[sensor and thermocouple for measuring pressure and applied Continuous Thread Closure type for sealing. There are many specifications and models according to customer requests.
Applications of High Pr]]></description><pubDate><![CDATA[20180919]]></pubDate></item>
<item>
<title><![CDATA[40 Channels Paperless Recorder]]></title><link><![CDATA[https://sheila6722.en.ec21.com/40_Channels_Paperless_Recorder--1858583_5524757.html]]></link><description><![CDATA[thermocouple, thermal resistance and other signals. It also has some other functions, including isolated power distribution output of sensors, relay alarm output, transmitter output, flow accumulatio]]></description><pubDate><![CDATA[20160229]]></pubDate></item>
<item>
<title><![CDATA[RexVa Heating Film (Milky)]]></title><link><![CDATA[https://gsbcrexva.en.ec21.com/RexVa_Heating_Film_Milky--3342470_9082294.html]]></link><description><![CDATA[thermocouple are attached to plates of copper measuring 65mm x 65mm x 0.5mm
Test for Estimating Product Life Sapn 
Check surface cracks of carbon heating element after testing repeatedly the followin]]></description><pubDate><![CDATA[20200428]]></pubDate></item>
<item>
<title><![CDATA[Dynisco Pressure Transmitter Injection Molding]]></title><link><![CDATA[https://contranspower.en.ec21.com/Dynisco_Pressure_Transmitter_Injection_Molding--9929422_9929979.html]]></link><description><![CDATA[Thermocouple or RTD configurations are available to provide melt temperature.
43. Dynisco pressure transmitter Melt Pressure Sensors with mV/V Outputs
Dynisco pressure transmitter Melt Pressure Senso]]></description><pubDate><![CDATA[20200828]]></pubDate></item>
<item>
<title><![CDATA[GE Gas Turbines]]></title><link><![CDATA[https://gzsrm.en.ec21.com/GE_Gas_Turbines--3084966_10191444.html]]></link><description><![CDATA[Sensors:
Roper Pumps &amp; Flowdividers
Thermocouples
Fuel Nozzle Repair &amp; Flowtest
Exhaust, Wheelspace
SPEEDTRONIC® Card Repairs
Bearing Drain
Servo Valve Repairs
RTD&apos;s
Check Valve Repairs
Flame Detect]]></description><pubDate><![CDATA[20220216]]></pubDate></item>
<item>
<title><![CDATA[Electronic Fire Assay Laboratory Cupellation Furnace /Calcining /Ashing Furnace]]></title><link><![CDATA[https://yosionlzw.en.ec21.com/Electronic_Fire_Assay_Laboratory_Cupellation--9926816_10781511.html]]></link><description><![CDATA[sensor: &quot;K&quot; thermocouple, high measurement accuracy;
Power supply: the furnace body is equipped with a 10A, single phase cable and plug, and the power load is 5A;
Pneumatic control furnace door openi]]></description><pubDate><![CDATA[20200302]]></pubDate></item>
<item>
<title><![CDATA[ABB  DCS Parts]]></title><link><![CDATA[https://willingtech.en.ec21.com/ABB_DCS_Parts--4887724_4887780.html]]></link><description><![CDATA[Thermocouple inputs-type B, C, E, J, K, L, N
200-PSMG 492898801 Power Supply Module
200-RANN 492852901 Rack Adaptor Board
200RB300002C Micro-Scan 200 Indicating Process Controller
200-TB3T 490176065 ]]></description><pubDate><![CDATA[20220825]]></pubDate></item>
<item>
<title><![CDATA[SX6000R Color Screen Paperless Recorder]]></title><link><![CDATA[https://silverellen.en.ec21.com/SX6000R_Color_Screen_Paperless_Recorder--6492514_6506253.html]]></link><description><![CDATA[thermocouple, thermal resistance and other signals. Paperless data recorder also has some other functions, including isolated power distribution output of sensors, relay alarm output, transmitter out]]></description><pubDate><![CDATA[20180918]]></pubDate></item>
<item>
<title><![CDATA[PVA film pods packing machine]]></title><link><![CDATA[https://dou008613823426744.en.ec21.com/PVA_film_pods_packing_machine--10531435_10531572.html]]></link><description><![CDATA[Sensor
Bonner
1
USA
Our Services
1) Warranty : 24 months (Attention: Machine&amp;#39;s warranty range don&amp;#39;t include damageable spare parts like heating tube, thermocouple, temperature controller, pho]]></description><pubDate><![CDATA[20171225]]></pubDate></item>
<item>
<title><![CDATA[Petrochemical Thermocouple(RTD)]]></title><link><![CDATA[https://jessie1109.en.ec21.com/Petrochemical_Thermocouple_RTD--5535463_5535359.html]]></link><description><![CDATA[The RTD/thermocouple is specially designed for application of petrochemical industry. The measurement range is -200&amp;deg;C-1600&amp;deg;C. And it can be applied in temperature measurement of liquid, steam]]></description><pubDate><![CDATA[20141022]]></pubDate></item>
<item>
<title><![CDATA[PC Based Sensor Trainer]]></title><link><![CDATA[https://iegieg.en.ec21.com/PC_Based_Sensor_Trainer--7052122_7052902.html]]></link><description><![CDATA[sensor module
Mirror reflective photo sensor module, Optical fiber sensor with amplifier module
Hall sensor module, Hall IC sensor module, Thermistor(NTC) module
Thermocouple module, PT thermistor mo]]></description><pubDate><![CDATA[20121231]]></pubDate></item>
<item>
<title><![CDATA[Digit LED Tube Voltage Current Power Meter Display HN-24SX]]></title><link><![CDATA[https://aoyijenny.en.ec21.com/Digit_LED_Tube_Voltage_Current--8875633_8878842.html]]></link><description><![CDATA[thermocouple K type-1350℃， the thermal resistance pt100 type 0 to 650℃.
Digit LED tube Voltage current power meter display HN-24SX
Technical Parameters:
Measure Precision: ±0.5% ±1Word
Workin]]></description><pubDate><![CDATA[20210619]]></pubDate></item>
<item>
<title><![CDATA[Process Control Regulation Teaching Aids]]></title><link><![CDATA[https://teachingequipment.en.ec21.com/Process_Control_Regulation_Teaching_Aids--8232359_8492704.html]]></link><description><![CDATA[thermocouple, electric control valve and so on, the commonly tools and plant parts and components constitute. Can finish level, pressure, flow, temperature sensors, transmitters, pipe valves and powe]]></description><pubDate><![CDATA[20150619]]></pubDate></item>
<item>
<title><![CDATA[Connection Head(01-01)]]></title><link><![CDATA[https://541200.en.ec21.com/Connection_Head_01_01--9521156_9521201.html]]></link><description><![CDATA[1.MATERIAL:ALUMINUM. 
2.SIZE: ID26mm. 
3.COLOR: SILVER(on request). 
More products,pls visit: www.nb-coshion.com]]></description><pubDate><![CDATA[20160506]]></pubDate></item>

</channel>
</rss>