There are 1309 air cooler from 495 suppliers on EC21.com
Related Searches : air conditioner , heat pump , air cooler , evaporative air cooler , chiller , cooler , thermostats
Supplier Info.
Report Item
Your report on Product(s), Selling Lead(s) will be sent to EC21 Administrators once submitted.
Then, Administrators will investigate and then take appropriate actions.
Contact Supplier
Product Keywords | small air conditioner,royal air cooling fan,rotating air cooler |
HVLS fans move slowly and distribute large amounts of air at low rotational speed– hence the name "high volume, low speed."
Evaporative Air Cooler designed by RDF are professional strong plastic structured models with axial fan, which needs to be installed with air ducting system. Fixed installation model is appropriate to be installed on solid places such as outside wall, grounds, concrete or Zinc-steel structured roof. Target Applications: Workshops, Factories, Supermarket, School&Church, Entertainment Centers.
As schematically shown, when the cooler is working, water is pumped from the tank to the water distributor, and distributed evenly to the vaporative cooling pads, then go back to the tank. Meanwhile, the outside hot air is drawn through the?wetted cooling pads and filtered and reduced in temperature before delivering to the user spaces.
Filtered and cooled by an evaporative air cooler, the outdoor fresh air is continuously sent into the indoor space through the air duct and air supply outlets. With the continuous supply of fresh air, the indoor space is in a positive pressure condition, thus the original hot air containing odor and dust will be emitted out of the room, resulting in a cool, ventilated, clean and comfortable environment. Suitable exhaust area and effective exhaust are essential for satisfactory performance of any evaporative air cooling system.
This zone is not applicable as in reality when the temperature is relatively high, RH is predominantly lower than the supply air temperature.With the wind-chill effect, the effective temperature for thermal human comfort is 1~2℃ lower than the Supply Air Temperature.
Amb. Temp | Relative Humidity | |||||||
20% | 30% | 40% | 50% | 60% | 70% | 80% | 90% | |
20 | 12 | 13 | 14.5 | 15.5 | 16.5 | 17.5 | 18.5 | 19.2 |
25 | 16 | 17 | 18.5 | 20 | 21 | 22 | 23 | 24 |
30 | 19.5 | 21 | 22.5 | 24 | 25 | 25 | 28 | 28.9 |
35 | 23 | 25 | 26.5 | 28.5 | 30 | 30 | 32.5 | 33.7 |
40 | 25.6 | 28.1 | 30.4 | 32.3 | 33.9 | |||
45 | 29.2 | 32 | 34.4 | |||||
50 | 32.7 | 35.8 |
Model | Discharge Type | Max Airfolw (m³/h) | Voltage Hertz Phase | Power Consumption (kw) | Evaporative Capacity (l/h) | Noise (db) | Water Tank (l) | Air Outlet (mm) | Unit Size (mm) | Net Weight (kg) |
RDF-18B | Bottom | 18000 | 220~240V/50Hz/1P 380~415V/50Hz/3P | 1.1 | 65 | 68 | 25 | 670*670 | 1100*1100*1000 | 60 |
RDF-18S | SIDE | 18000 | 220~240V/50Hz/1P 380~415V/50Hz/3P | 1.1 | 65 | 68 | 35 | 670*670 | 1100*1100*1000 | 67 |
RDF-18T | TOP | 18000 | 220~240V/50Hz/1P 380~415V/50Hz/3P | 1.1 | 65 | 68 | 35 | 730*730 | 1100*1100*1020 | 57 |
High efficiency cooling pad
Innovative frequency conversion control design
Water spray resistance grille in streamline design
Multiple anti-blocking filter net
Motor with low failure and high temperature resistance
Simulation fluid dynamics design
High efficiency cooling pad
Multiple anti-blocking filter net
Open soft pipe water distribution system
Multiple anti-blocking filter net
High quality and durable water pump
Automatic water replenishment design
High strength weathering frame
Innovative design for cooling pad with PVC frame
High strength pillars
Chassis in AIO design
Humanized chassis button
Strong and durable motor support
Air exchange frequency(times/h)=total air flow rate(m3/h) ÷ indoor space volume.
20~30 times per hour for general environment;
30~40 times per hour for crowded public place;
40~50 times per hour for workshop with heating equipment;
50~60 times per hour for workshop with high temperature and high air pollution;
Air exchange frequency can be increased in damp areas, and decreased in dry places.
Cooler quantity needed = indoor space volume × air exchange frequency ÷ cooler air flow rate.
Spot cooling projects shall varies based on actual situation.
The ducting system shall be matched with the air cooler model, and air outlet quantity shall be considered when designing.
Cooling Equipment | |||||||
Type | ![]() | Evaporative Air Cooler | ![]() | Air Conditioning | ![]() | Ventilation Fan | |
Capacity | 18000m³/h | 400000 BTU/h | 40000m³/h | ||||
kw | 1.1 | 54 | 1.1 | ||||
Workspace | Area(㎡) | 1000 | 1000 | 1000 | |||
Effective Height(m) | 4 | 4 | 4 | ||||
Air Change Per Hour | 30 | Recirculating | 30 | ||||
Electrical Energy Consumed | Total Units Insalled | 10 | 2 | 8 | |||
Total KW Insalled(kw) | 11 | 108 | 8.8 | ||||
Electrical Units Consumed @10hrs/days @26day/mth | 34320 KW/YEAR | 336960 KW/YEAR | 27456 KW/YEAR | ||||
Cost Conparison With Reference to AC | 10.1% | 100% | 8% | ||||
Effects Of Various Cooling Methods | Pushes out hot, taste air and ventilates with Cool Clean & Fresh Air. | Circulates air inside only It is ineffective in heat generating space | Only moves ambient air but offers no relief as temperature rises. |
Registration Date | 2019/07/26(Year/Month/Date) |
---|---|
Buyer / Seller in EC21 | Seller |
Business Type | Manufacturer |
Year established | 2003 |
Employees total | 101 - 500 |
Annual revenue | USD 1,000,001 - 2,000,000 |
Company | Kool Air International Co., Ltd |
---|---|
Address | NO.83 Fenxi Rd,Wanjiang DistrictDongguanGuangdongChina |
Phone | 86 - 0769 - 4008877422 |
Contact | Allen Yang |