1、Software function summarize
The series BTS TestControl software is a range of control system in NEWARE BTS batteries testing system, it only be used after connecting to batteries testing cell. This software suite aim at the batteries testing system, it is consist of nine applications:
Boost up: Sets step to the battery channel, the channel will work immediately according to the work-step after starting. The step includinge constant current charge, constant voltage charge,constant current and voltage charge, constant current discharge, constant Power Discharge, rest, cycle, stop.
Stop: When one channel is working, it will stop automatically after completes all step. At the some time, users can stop it forcibly as necessary.
Connection: For some channels which have stopped (including stop by users, safe stop) can use “connection” function to restore the original test process and maintain the data connection.
Jump: The running step can be stopped forcibly by users to jump to the assigned step to continue.
Work-step migration
Reset step
Copy step
Channel information: Inquiring the condition of channel which is working.
Open data: Users can open the recording data to process.
Auxiliary channel: (In perfection)
2、Neware Battery Testing System Software startup
After installing, finds TC53 in the desktop. Double-clicks then can start the testing system control procedure. BTS TestControl will detect automatically whether all modules are on line in the battery testing system. (The number of on-line chassis is listed as below).
2.1、Software interface specification
The following chart will be shown after you start this software (Notice: before start, the cell equipment and PC computer must be connected via a serial-port online)
In the graph, where the numbers pointed to has respectively means:
1. The fundamental equipment
Normal direction flow: Chassis number search set, equipment search, select language, show/hide set and help.
Chassis number search set: You can set the search maximum chassis number.
Language select: You can select the language you want to use. (Chinese simplified, Chinese Traditional, English. It is effective only be restarted next time. )
Show/hide set: You can set the display status of left side column.
Help: Help you solve the questions you met when you use this system.
2. The fundamental information of chassis number
Here display the number of current online chassis, hardware version and type.
3. The status display of each channel; Last one is some basic information of testing system.
4. Left side column: You can search and view the historical information here. Left side column is floating.
5. Select display mode: Systems are custom displayed the content of information according to different needs.
[The right key of mouse]
BTS TestControl frequently uses the right key of mouse, clicks with the right key of mouse at different positions of the interface to pop out different floating menu, and complete all operation which needs.
3、Neware Tc53 Control Operation
3.1、Look over operation
Here, only view channel number for has not worked channel, like 2-1 would represent the second box in one channel, simultaneously, outline of batteries inferior fovea. For has stopped or the protective channels which only display channel number, date and status, simultaneously, outline of batteries inferior fovea; For the channels which are working, besides displaying channel number, it also display cycle times (in the top right corner), voltage(V), current(mA),capacity(mAh) from the top down take turns. If it is in charge condition, the top left-hand corner will dynamic display a downward blue arrow. If in discharge condition, then the top left-hand corner will dynamic display an upward red arrow. If in stewing condition (not charge and discharge), there will no arrow.
As the chart shows, it will pop out two kinds of floating menus, if click with the right key of mouse in the different condition channels (one and two projects are grayed is different), by now, if all channels which are chosen is working, it can carry out theoperations of stop, jump, reset step and so on; If the chosen channels which are not working, it can carry out start. In addition, if only chosen one channel which is working, it also can carry out the operations of channel information, open data and so on; if the channel is in off condition, it can carry out the operation of open data.
[How to choose channel]:
Clicks the battery outline of channel with the left key of mouse to appear a yellow frame, which would mean this channel has been selected. If need to select several channels which are discontinuity, presses Ctrl key and selects one channel after
another with the left key of mouse. If need to select several channels which are continuous, at first using the left key of mouse to take the first one and press Shift key then it will be possible to achieve many channels of continual selection; Or holds down the left key of mouse to drive in the scope which is needed.
2. Detail view
Want to see related data operations, please reading BTSDA.
3.2 Startup
Designates one or more channels which don't work, single-clicks with the right key of mouse, chooses startup in the appearing menu to enter into the dialog box of step set. After completing the set so can establish that we have completed the start and thechannel which is selected starts to run according to your establishment.
In the step set dialog box, users can set the flow of work and edit the parameter of each step, also can set from startup, in which each work step can set corresponding limit conditions according to the different work mode, which can be constant current charge, constant current discharge, constant voltage charge, static, circle and stop, etc. The limit condition "current" must be set to the constant current charge, constant voltage charge. Others only establish one or simultaneously designate several "constant voltage charge" must be established, and "current" refers to cut off current in the constant voltage charge. Speaking of the limit condition, it express does not use this limit condition if fill in data by mistakes. If has used many
limit conditions for some steps, the relation of them is "logic or” There are three options: time interval voltage interval and current interval are included in the data record condition after setting step, It is effective when choose several simultaneously. The relation of each recording condition is logic or, records the data if the random item is satisfied. The data profile can be lost as small as possible if select recording condition appropriately and not omit the key data, also can enhance the speed of data processing. The content of basic information can be log to data document automatically to prepare to query and print.
"Safe protective" is mainly aim at abnormal channel which is for battery current, voltage sampling in the testing procedure to protect hardware. Take the lithium battery for example: it discharge voltage is 2.75V, charge voltage is 4.20V, and safe protection parameter boundary voltage can be reference set as 2.5~4.3V. This system defines charge current as "+", discharge as"-". Must pay more attention when set safe protection, for example set charge and discharge current as 700mA, the data of current ranges ± in safe protective must be higher than 700mA, not the current deviation. When execute save file (S),open file (O) command, all files of step can save and open to convenient for later work. Each flow can set 64 steps .It will stop automatically after executing the last step. In normal view, the battery symbol will display the completed
wording. If there is a problem before establishing the step, it must be reset, then click clear step to reset.
3.3 Stop
Selects one or more channels which are working, single-clicks with the right key of mouse, chooses stop in the pop out menu, so you can carry out the stop operation in the selected channels.
3.4 Jump
Selects one or more channels which are working, single-clicks with the right key of mouse, chooses jump in the pop out menu to enter into the jump to dialog box, the chart shows as below:
In this dialog box, click some row in the step column or enter the number of step which will jump to in the bottom left corner then jump to the appointed step after establishment.
3.5 Connection
For the channels which used to work, present is at the stop status, clicks with the rightkey of mouse, and selects "connection" in the pop out menu to restore the originaltesting work in the designated channels, the data maintenance connection. [Note] Cooperate to use "stop" and "connect” functions to achieve the suspension and restore in the testing channel work. The channels which are complete the test and deletion condition information can't connect. After the procedure withdraw or power off forcefully, it will restart and system can continue automatically.
Registration Date | 2014/11/18(Year/Month/Date) |
---|---|
Buyer / Seller in EC21 | Seller |
Business Type | Manufacturer |
Year established | 1998 |