Hebei Create Instrumentation Technologies Co., Ltd. are the leading supplier of water quality instrumentations with history of 25 years.
Our production line covers :
- Reverse Osmosis Controller.
- Conductivity/ Resistivity Meters & Transmitters.
- pH /ORP Meters & Transmitters.
- Flow Meter and Sensors.
-Optical Dissolved oxygen controller
-COD and BOD analyzer
-Ammonia Nitrigen analyzer
- Free Chlorine Systems.
-Turbidity Analyzers.
-Online multi-parameter system integration DCS-8600 (customization one)
-EDI Module for the ultra pure water product
-Hardness
-Dosing pumps
-Ozone analyzer
Series Chlorine analyzer (DPD method) measure at 0.01 ~0.05 mg/L, Better than the sensor type Chlorine analyzer.
Summary | ||
Display screen | 7 inch colour touch screen | |
Dimension | 730(H)*500(W)*280mm(D) | |
Weight | About 20kg(excluding reagent) | |
Installation | Wall type or bracket | |
Sample requirements | ||
Influent flow range | 300-1200 mL/min | |
Sample temperature range | 0-40℃ | |
Sample pipeline | The instrument is equipped with 5 meters of 1/4 "PE fine plastic pipe, connecting inlet 1/4" fast partition joint. | |
Drainage pipeline | The instrument is equipped with 2 meters of 3/8"PE pipe, connecting inlet 3/8" fast partition joint. | |
Reagent | ||
Reagent container | 3*500mL thick plastic reagent bottle | |
Reagent installation | The reagent bottle is fixed on the reagent rack, lack reagent alarm will remind with remaining 20% reagent. | |
Electrical Specifications | ||
Power supply | 220V AC, 50/60 Hz | |
Power connection | The power cord with 3 cores and plugs is connected to the mains socket with ground | |
Leakage protection | IC65N 10A/2P 30mA AC220V | |
Data output | RS485 serial communication; | |
Instrument performance | ||
Measuring method | N,N-diethyl-1,4-phenylenediamine(DPD)spectrophotometry(GB 11898-89) | |
Measurement range | 0-1mg/L ,1-5mg/L | |
Accuracy | 0-1.0mg/L:± 0.05mg/L in Cl2; 1.0-5.00mg/L:relative error±5% in Cl2 |
|
Measurement period | 5min/time | |
Measurement interval | 1-999 minutes interval can be set, or hourly measurement can be selected. | |
Lower limit | 0.005mg/L | |
Instrument calibration | Zero point calibration, the slope calibration | |
Environment | ||
Storage temperature range | Temperature:-10-50℃(No Condensation) | |
Range of application | Temperature: 0-40℃,no icing | |
Relative environment humidity | Relative humidity:≤85%RH(noncondensable) |
Registration Date | 2015/05/14(Year/Month/Date) |
---|---|
Buyer / Seller in EC21 | Seller |
Business Type | Manufacturer |
Year established | 2006 |
Employees total | 101 - 500 |
Annual revenue | USD 5,000,001 - 10,000,000 |
Company | Hebei Create Instrumentation Technologies Co., Ltd |
---|---|
Address | No.368 XinshiShijiazhuangHebeiChina |
Phone | 86 - 0311 - 83056 |
Contact | Liceya |