Search Advanced Search
Products > specification > Lisun Group | Similar Products
Your search for "

specification

" found 12 Products from Lisun Group, China

(1-12 out of 12)

Automatic Safety Test System

Automatic Safety Test System
The LS9955/LS9956 Automatic Safety Test System (electrical safety analyzer) combined the following function in one set: Withstand Voltage Test (AC/DC), Insulation Resistance Test (IR), Leakage ...

Needle Flame Test

Needle Flame Test
According to IEC60695-2-2, IEC60695-11-5, IEC62368-1 and GB/T-5169.5, ZY-3/ZY-3S needle flame test equipment is applied in the production and quality control department of lighting products, ...

Glow-wire Test Apparatus

Glow-wire Test Apparatus
Specifications:• Heating temperature: adjustable continuously within the range of 25~1100°C, the accuracy of temperature is 1°C, the resolution of temperature is ±3°C• Glow-wire time: ...

Surge Generator

Surge Generator
The SG61000-5 is an automatic surge generator (also called lightning surge immunity test, combination wave generator, surge current generator/surge voltage generator, combined surge voltage and ...

ESD Simulator Guns

ESD Simulator Guns
Specifications: Product ModelESD61000-2ESD61000-2AOutput Voltage0.1~20kV±5%0.1~30kV±5%PolarityPositive/NegativePositive/NegativeEnergy Storage Capacitance150pF±10% (Replaceable)150pF±10% ...

EMI Test Receiver

EMI Test Receiver
Specification:• Detection frequency range: 9kHz~1GHz (EMI-9KC), 9kHz~300MHz (EMI-9KB), 9kHz~30MHz (EMI-9KA) • Frequency stability: 1×10^-6• Frequency resolution: (9kHz~150kHz) 30Hz; (150kHz~30MHz) ...

LED Power Driver Tester

LED Power Driver Tester
LS2090 LED Power Driver Test Instrument is the comprehensive test instrument for LED driver power which is according to GB/T 24825-2009 and IEC 62384:2006. It can measure the following parameters: ...

High Precision Spectroradiometer Integrating Sphere System

High Precision Spectroradiometer Integrating Sphere System
Specification:• Spectral Wavelength Accuracy: ±0.3nm, Wavelength Reproducibility: ±0.1nm• Sample Scanning Steps: ±0.1nm• Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.002 (under Standard A Lamp)• ...

CCD Spectroradiometer Integrating Sphere Compact System

CCD Spectroradiometer Integrating Sphere Compact System
Specification:• Spectral Range Wavelength: 350nm~950nm(LMS-7000VIS) (200~1050nm is optional)• Spectral Wavelength Accuracy: ±0.5nm Wavelength Reproducibility: ±0.5nm• Sample Scanning Steps: ±0.1nm• ...

Portable CCD Spectroradiometer

Portable CCD Spectroradiometer
and IEEE. The Chroma Meter Specifications:• Spectral resolution: ±0.2nm, Reproducibility: ±0.5nm• Accuracy of chromaticity coordinate (Δx, Δy): ±0.005• Correlated color temperature CCT: 1, 500K ~ 100 ...

High Precision Rotation Luminaire Goniophotometer

High Precision Rotation Luminaire Goniophotometer
Specification:• The goniophotometric instrument can do the B-β test with two pillars and the C-γ test with single pillar & multi-function jigs• Test Max Luminaires size and weight: LSG-1890B is ...

LM-79 Moving Detector Goniophotometer (Mirror Type C)

LM-79 Moving Detector Goniophotometer (Mirror Type C)
Specifications:• The mirror and detector rotates around the luminaire under test with an angle of (γ) vertical axis ±180° (or 0-360°) and the luminaire rotates around itself with an angle of (C) ...
Page 1 of 11
Go to Page Go