WINNER319 Industrial Spray Particle Size Analyzer

This company has a company video.
WINNER319 Industrial Spray Particle Size Analyzer
Rate ≧2KHZ Laser LD Pump Laser;λ=532nm , p>40mw, life time>25000 hour Laser safety Class 3B Air purging system Equipped with airflow protection device, which can effectively protect the lens and ...

Winner2308B Intelligent Wet and Dry Laser Particle Size Analyzer

This company has a company video.
Winner2308B Intelligent Wet and Dry Laser Particle Size Analyzer
Rated Flow:30L/min Rated Power:70WAnti-overflow sensorMade in SST , UKSample tankVolume:1000mLMicro-Sample cuvetteVolume: 10mL ( Available)Dry dispersionDry-turbulence dispersion patent technology, ...

Winner2308A Intelligent Fully Automatic Wet and Dry Particle Size Analyzer

This company has a company video.
Winner2308A Intelligent Fully Automatic Wet and Dry Particle Size Analyzer
Rated Flow:30L/min Rated Power:70WAnti-overflow sensorMade in SST , UKSample tankVolume:1000mLMicro-Sample cuvetteVolume: 10mL ( Available)Dry dispersionDry-turbulence dispersion patent technology, ...

WINNER2006B Intelligent Wet Laser Particle Size Analyzer

This company has a company video.
WINNER2006B Intelligent Wet Laser Particle Size Analyzer
sample) Repeatability error ≤0.5% (Deviation of D50 on national standard sample) Laser parameters Main laser source: high-performance laser λ= 632nm, power P>2mw Auxiliary laser source: semiconductor ...

WINNER2006A Intelligent Wet Laser Particle Size Analyzer

This company has a company video.
WINNER2006A Intelligent Wet Laser Particle Size Analyzer
sample) Repeatability error ≤0.5% (Deviation of D50 on national standard sample) Laser parameters Main laser source: high-performance laser λ= 632nm, power P>2mw Auxiliary laser source: semiconductor ...

WINNER2018 Auto Wet Laser Particle Size Analyzer

This company has a company video.
WINNER2018 Auto Wet Laser Particle Size Analyzer
Overview: Winner2018 intelligent laser particle size analyzer, perform auto test, auto alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion, auto cleaning ...

Winner 99E Static Image Particle Size Analyzer

This company has a company video.
Winner 99E Static Image Particle Size Analyzer
rate equalization and boundary detection and other Binarization methods, greatly improves the data processing and analysis capabilities. It reduces the complexity of user operation, improve the ...

Winner300D Dynamic Particle Image Analyzer

This company has a company video.
Winner300D Dynamic Particle Image Analyzer
samples in different sampling periods can be obtained) Analysis Software Function: 1) Task management mechanism: according to the task management, ensure that the data management is in good order. 2) ...

WINNER319 Industrial Spray Laser Particle Size Analyzer

This company has a company video.
WINNER319 Industrial Spray Laser Particle Size Analyzer
Rate ≧2KHZ Laser LD Pump Laser;λ=532nm , p>40mw, life time>25000 hour Laser safety Class 3B Air purging system Equipped with airflow protection device, which can effectively protect the lens and ...

Winner2308B Intelligent Wet and Dry Integrated Laser Particle Size Analyzer

This company has a company video.
Winner2308B Intelligent Wet and Dry Integ<strong>rate</strong>d Laser Particle Size Analyzer
Rated Flow:30L/min Rated Power:70WAnti-overflow sensorMade in SST , UKSample tankVolume:1000mLMicro-Sample cuvetteVolume: 10mL ( Available)Dry dispersionDry-turbulence dispersion patent technology, ...

Winner2308A Intelligent Fully Automatic Wet and Dry Integrated Laser Particle Size Analyzer

This company has a company video.
Winner2308A Intelligent Fully Automatic Wet and Dry Integ<strong>rate</strong>d Laser Particle Size Analyzer
Rated Flow:30L/min Rated Power:70WAnti-overflow sensorMade in SST , UKSample tankVolume:1000mLMicro-Sample cuvetteVolume: 10mL ( Available)Dry dispersionDry-turbulence dispersion patent technology, ...

WINNER2006B Intelligent Wet Laser Particle Size Analyzer Particle Size Instrument

This company has a company video.
WINNER2006B Intelligent Wet Laser Particle Size Analyzer Particle Size Instrument
sample) Repeatability error ≤0.5% (Deviation of D50 on national standard sample) Laser parameters Main laser source: high-performance laser λ= 632nm, power P>2mw Auxiliary laser source: semiconductor ...

WINNER2006A Intelligent Wet Laser Particle Size Analyzer Particle Size Instrument

This company has a company video.
WINNER2006A Intelligent Wet Laser Particle Size Analyzer Particle Size Instrument
sample) Repeatability error ≤0.5% (Deviation of D50 on national standard sample) Laser parameters Main laser source: high-performance laser λ= 632nm, power P>2mw Auxiliary laser source: semiconductor ...
Page 1 of 11
Go to Page Go

Browse: Manufacturer Directory Premium Suppliers Site Map

About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838

Inquiry Basket ()