- Group Products
- All Products
- 1 Product Per Company
- Supplier Country
-
- Korea
- View All
- Search Options
- Show Premium Suppliers
- Subscription
- Trade Alert
Notify me of new ndir sensor info. - RSS Feeds
- My Recent History
Place of origin:
Korea
Price Condition:
FOB
NDIR (Non-dispersive Infrared) Measurement Range : 0 ~ 2,000(3,000/5,000/10,000ppm, 5% are available) Accuracy : ±50ppm ±3% of reading (±300ppm ±3% of reading - 5% model) Response Time (1/e) : 120 seconds Sampling Interval : 3 seconds Electrical Data Power Input : 12VDC(9~15VDC) (2% Regulation) Current Consumption : Normal mode : 33mA, Peak : 230mA at lamp on pe
[Related Keywords : CO2 Sensor, CO2 Sensor Module, Gas Sensor, NDIR Sensor]
Business Type
Manufacturer
Location
Gyeonggi-do, Korea
Employees Total
11 - 50
Annual Revenue
USD 5,000,001 - 10,000,0000
Min. Order:
1 Set
Price:
US$ 1290~1390
Place of origin:
Korea
Supply Ability:
500 set / per month
Sensor Theory CO, HC, CO2, Non-Dispersive Infrared Analysis(NDIR) O2, NOX: Electrochemical Cell CO HC CO2 Measuring range 0.00 ~ 10.0% 0 ~ 9999 ppm 0.0 ~ 20.0% Resolution 0.01% 1 ppm 0.10% O2 λ AFR NOX Measuring range 0.00 ~ 25.00 % 0 ~ 2.000 0.0~99.0 0 ~ 5,000 ppm Resolution 0.01% 0.001 0.1 1ppm Display 4 digit 7segment LED Repetition Rate Less than 2% FS Response time Within 10
[Related Keywords : Automotive emission gas analyzer, exhaust gas analyzer, gas analyzer, Diesel smoke meter]
Business Type
Manufacturer
Location
Seoul, Korea
Employees Total
11 - 50
Annual Revenue
USD 5,000,001 - 10,000,0000
Place of origin:
Korea
Price Condition:
FOB
MT100 series are world’s smallest USB CO2 Monitor which work with Desk-Top or Notebook and Smart-Phone. General Performance Operating Temperature : -0 ~ 50℃ Operating Humidity : 0 ~ 95% RH (Non-condensing) Storage Temperature : -30℃ ~ 70℃ Measurement CO₂ Sensing Method : NDIR (Non-dispersive Infrared) Measurement Range : 0 ~ 10,000ppm Accuracy : ±70ppm ±3% of
[Related Keywords : CO2 Monitor, Air Quality Monitor, NDIR Gas sensor, USB gas sensor]
Business Type
Manufacturer
Location
Gyeonggi-do, Korea
Employees Total
11 - 50
Annual Revenue
USD 5,000,001 - 10,000,0000
Place of origin:
Korea
Price Condition:
FOB
1. CD-200 (Relay Output Model) CD-200 series are Transmitter type models of CO2 Sensor, which give current output or voltage output (Jumper selectable). They are 4 + 2 wired (2 Power lines, 2 signal lines and 2 relay lines) . General Performance Operating Temperature : -10 ~60℃ Operating Humidity : 0 ~ 95% RH (Non-condensing) 'G' option - 0 ~ 99% RH (Non-condensing) Storage Temper
[Related Keywords : CO2 Transmitter, Gas sensor, CO2 sensor, NDIR Gas sensor]
Business Type
Manufacturer
Location
Gyeonggi-do, Korea
Employees Total
11 - 50
Annual Revenue
USD 5,000,001 - 10,000,0000
Place of origin:
Korea
Price Condition:
FOB
i. CD-100(G) series are one board analog output type transmitters of CO2 Sensor, which are 4-wired or 3-wired supporting. ii. CD-100M(LG) series are one board RS-485 MODBUS type transmitters of CO2 Sensor. Temperature and relative humidity can be selectable. iii. CD-100-BZ series are one board analog output type transmitters of CO2 Sensor, which could operate at below zero down to -40℃ iv. C
[Related Keywords : CO2 transmitter, CO2 Sensor, CO2 Sensor Module, Gas Sensor]
Business Type
Manufacturer
Location
Gyeonggi-do, Korea
Employees Total
11 - 50
Annual Revenue
USD 5,000,001 - 10,000,0000
Place of origin:
Korea
Price Condition:
FOB
NDIR (Non-dispersive Infrared) Measurement Range : 0 ~5,000ppm Accuracy : ±50ppm ±5% of reading with ACDL Logic Condition Response Time (1/e) : 120 seconds Sampling Interval : 3 seconds Electrical Data Power Input : 4.75V ~ 5.50V (5.0V ± 5% Regulation) Current Consumption : Normal mode : 6.4mA, Peak : 312mA at lamp on peak Product Derivatives with Functions Products O
[Related Keywords : IoT Sensor module, Gas sensor module, CO2 sensor module, NDIR sensor]
Business Type
Manufacturer
Location
Gyeonggi-do, Korea
Employees Total
11 - 50
Annual Revenue
USD 5,000,001 - 10,000,0000
Place of origin:
Korea
Price Condition:
FOB
1. D-300 (5V Model) D-300(LG) series is the smallest Dual CO2 sensor module in the world. Its Persistent Stability and Temperature Effect Resistance are much favored in warehouse, greenhouse, hospitals etc. besides the small size and consistent accuracy through the life cycle. General Performance Operating Temperature : -20 ~ 50℃ Operating Humidity : 0 ~ 95% RH (Non-condensing), 'G'
[Related Keywords : Dual sensor, CO2 sensor, NDIR CO2 sensor, Gas Sensor Module]
Business Type
Manufacturer
Location
Gyeonggi-do, Korea
Employees Total
11 - 50
Annual Revenue
USD 5,000,001 - 10,000,0000
Place of origin:
Korea
Price Condition:
FOB
NDIR (Non-dispersive Infrared) Measurement Range : 0 ~ 2,000(3,000/5,000/10,000ppm are available) Accuracy : ±30ppm ±3% of reading Response Time (1/e) : 90 seconds Sampling Interval : 3 seconds Electrical Data Power Input : 5V ± 5% Current Consumption : Normal mode : 14mA, Peak : 230mA Product Derivatives with Functions Products Option List S-110(G) Calibration: H/W
[Related Keywords : CO2 Sensor, NDIR CO2 sensor, Gas sensor, Carbon Dioxide sensor]
Business Type
Manufacturer
Location
Gyeonggi-do, Korea
Employees Total
11 - 50
Annual Revenue
USD 5,000,001 - 10,000,0000
Place of origin:
Korea
Price Condition:
FOB
NDIR (Non-dispersive Infrared) Measurement Range : 0 ~ 2,000(3,000/5,000/10,000ppm are available) Accuracy : ±50ppm ±3% of reading Response Time (1/e) : 120 seconds Sampling Interval : 3 seconds Electrical Data Power Input : 4.75V ~ 5.25V (5.0V ± 5% Regulation) Current Consumption : Normal mode : 14mA, Peak : 230mA at lamp on peak Product Derivatives with Functions Pr
[Related Keywords : CO2 Sensor Module, CO2 Sensor, Gas Sensor, NDIR CO2 sensor]
Business Type
Manufacturer
Location
Gyeonggi-do, Korea
Employees Total
11 - 50
Annual Revenue
USD 5,000,001 - 10,000,0000
Place of origin:
Korea
Price Condition:
FOB
1. T-110 (5V Model) T-110 is the world’s lightest and smallest CO2 sensor modules. Their easy management besides Persistent Stability and Temperature Effect Resistance are much favored by mobile application which needs sleep mode support, so on. General Performance Operating Temperature : 0 ~ 50℃ Operating Humidity : 0 ~ 95% RH (Non-condensing) Operating Environment : Residential, Co
[Related Keywords : CO2 Sensor Moduel, CO2 Transmitter, Air Quality Monitor, Gas Sensor Module]
Business Type
Manufacturer
Location
Gyeonggi-do, Korea
Employees Total
11 - 50
Annual Revenue
USD 5,000,001 - 10,000,0000
Place of origin:
Korea
Price Condition:
FOB
1. S-300 (5V Model) S-300(LG) series is one of world’s smallest NDIR CO2 sensor module, of which persistent Stability and Temperature effect resistance besides various outputs are much favored by customers in stocks raising, greenhouse, HVAC, scientific projects, etc. General Performance Operating Temperature : -20℃ ~ 50℃ (Option : -10℃ ~ 60℃) Operating Humidity : 0 ~ 95% RH (Non
[Related Keywords : CO2 Sensor Module, CO2 transmitter, Air quality Monitor, CO2 Sensor]
Business Type
Manufacturer
Location
Gyeonggi-do, Korea
Employees Total
11 - 50
Annual Revenue
USD 5,000,001 - 10,000,0000
Place of origin:
Korea
Price Condition:
FOB
NDIR (Non-dispersive Infrared) Measurement Range : 0 ~ 2,000(3,000/5,000/10,000ppm are available) Accuracy : ±50ppm ±3% of reading Response Time (1/e) : 90 seconds Sampling Interval : 3 seconds Electrical Data Power Input : 12V (9~18VDC, ±10% Regulation) Current Consumption : Normal mode : 14mA, Peak : 145mA at lamp on peak Output connector : 11 pin header connector (
[Related Keywords : CO2 Sensor, CO2 Sensor Module, Gas Sensor, NDIR Sensor]
Business Type
Manufacturer
Location
Gyeonggi-do, Korea
Employees Total
11 - 50
Annual Revenue
USD 5,000,001 - 10,000,0000
Competitive ndir sensor products from various ndir sensor manufacturers and ndir sensor suppliers are listed above, please select quality and cheap items for you.
![]() |
Recommended Content