- Power
- Electronic (26)
- Usage
- Group Products
- All Products
- 1 Product Per Company
- Search Options
- Show Premium Suppliers
- Subscription
- Trade Alert
Notify me of new temp. info. - RSS Feeds
- My Recent History
Min. Order:
1 Unit
Price:
US$ 9255.55 ~ 12955.95
Place of origin:
Singapore
temp (40 mK)*Level and spanSmooth auto and manual scaling, in SmartView desktop softwareFast auto toggle between manual and auto modesYes, in SmartView R&D™ desktop softwareFast auto-rescale in manual modeYes, in SmartView R&D™ desktop softwareMinimum span (in manual mode)0.1 °C (0.18 °F), in SmartView R&D™ desktop softwareMinimum span (in auto mode)<1.0 °C (<1.8 °F), in SmartView R&D
[Related Keywords : Fluke Thermal Imager, Thermal Imager, Analyzer, Calibration]
Business Type
Supplier
Location
Singapore, Singapore
Employees Total
6 - 10
Annual Revenue
USD 1,000,001 - 2,000,000
Min. Order:
1 Unit
Price:
US$ 3955.55 ~ 4265.95
Place of origin:
Singapore
Temperature measurement Temperature measurement range (not calibrated below -10 °C): ≤-20 °C to 1000 °C (-4 °F to 1832 °F)Accuracy: ±2 °C or 2% (at 25 °C nominal, whichever is greater)Thermal sensitivity (NETD)*: ≤0.05 °C at 30 °C target temp (50 mK)On-screen emissivity correction: Yes (both value and table)On-screen reflected background temperature compensation: YesOn-screen transm
[Related Keywords : Thermal Camera, Analyzers, Electical Testing, Digital Multimeter]
Business Type
Supplier
Location
Singapore, Singapore
Employees Total
6 - 10
Annual Revenue
USD 1,000,001 - 2,000,000
Min. Order:
10 Unit
Price:
US$ 155.25 ~ 195.29
Place of origin:
Singapore
temperature range-20 to 400°C (-4 to 752°F)AccuracyAt ambient temp. 15 to 35°C (59 to 95°F) and object temp. above 0°C (32°F)0 to 100°C (32 to 212°F): ±3°C (±5.5°F)100 to 400°C (212 to 752°F): ±3%Measurement functionsSpotBox with max./min.Measurement correctionEmissivity; matt/semi-matt/semi-gloss + custom valueReflected apparent temperatureAtmospheric compensationImage Storage & S
[Related Keywords : Thermal Camera, Thermal Imagers, Fluke Calibration, Ground Testers]
Business Type
Supplier
Location
Singapore, Singapore
Employees Total
6 - 10
Annual Revenue
USD 1,000,001 - 2,000,000
Min. Order:
1 Unit
Price:
US$ 1990 ~ 3990
Place of origin:
Singapore
temp (50 mK) Temperature measurement range (not calibrated below -10 �C): ?-10 �C to +1000 �C (14 �F to 1832 �F) Accuracy: � 2 �C or 2% (at 25 �C nominal, whichever is greater) Reduce need take notes in field with IR-PhotoNotes and voice annotations Increased sensitivity to visualize differences Capture smaller temperature differences with increased thermal sensitivity Easier to v
[Related Keywords : Thermal Camera, Infrared Camera, Fluke Camera, Biomatric]
Business Type
Supplier
Location
Singapore, Singapore
Employees Total
6 - 10
Annual Revenue
USD 2,000,001 - 5,000,000
Min. Order:
1 Unit
Price:
US$ 5899 ~ 6990
Place of origin:
Singapore
Temperature measurementTemperature measurement range (not calibrated below -10 °C)-20 °C to 1000 °C (-4 °F to 1832 °F)Accuracy±2 °C or 2% (at 25 °C nominal, whichever is greater)Thermal sensitivity (NETD)*≤ 0.05 °C at 30 °C target temp (50 mK)On-screen emissivity correctionYes (both value and table)On-screen reflected background temperature compensationYesOn-screen transmission correc
[Related Keywords : Fluke Camera, Thermal Cameras, Theodolite, GeoMax]
Business Type
Supplier
Location
Singapore, Singapore
Employees Total
1 - 5
Annual Revenue
USD 1,000,001 - 2,000,000
Min. Order:
1 Unit
Price:
US$ 3055.05 ~ 3955.55
Place of origin:
United States
temperature ranges quickly with color alarmsMore intuitive visual interface, improved, user-tested, touch screen interfaceTech SpecsThermal Imagers/Building and Industrial Thermal Imagers TemplateDetector Size640 x 480 SensorThermal Sensitivity50 mK (NETD)Temperature Range Max1832 FTemperature Range Min-14 FImage Frequency60 HzField of View34 x 24 DegreesScreen Size3.5 INIR/Overlay Fusion ImageYe
[Related Keywords : Thermal Imager, Tester Calibration, Total Station, Thermal Camera]
Business Type
Supplier
Location
Selangor, Malaysia, Malaysia
Employees Total
6 - 10
Annual Revenue
USD 1,000,001 - 2,000,000
Place of origin:
China
Supply Ability:
2000 pcs/ month
Temp. 20℃±2℃ Developing Time: 5 min. Density: 1.5 Input Voltage AC 198-242V / 50-60Hz Capacity 2.5KW Output Tube Voltage 30-100KV 30-100KV 60-160KV 80-160KV 60-160KV 100-200KV 100-200KV Tube Current 5mA Fluctuation ±2% X-ray Tube Focal Spot Size 0.8×0.8 1.0×2.0 1.0×3.0(Z) 0.8×0.8 1.0×2.0 1.0×3.0(Z) 1.5×1.5 1.0×2.0 1.0×3.5(Z) Radiation Coverage 40° 360°×25° 360°×40°(Z) 40° 3
[Related Keywords : controller]
Business Type
Manufacturer
Location
Hebei, China
Employees Total
101 - 500
Annual Revenue
USD 1,000,001 - 2,000,000
Place of origin:
China
Supply Ability:
5000 sets per month
Temperature affect test: 2 hours, -40°c ~+70°c Moisture and heat performance test,24hours. high temp. 55°c, low-temp 25°c, humidity 93% Short circuit current impact test, 16KA, 2 second Insulator Test: 1) Insulator resistance test ≥10 MΩ 2) Dielectric strength test, 1min,AC 2KV. IP protection level test, IP67: Anti –dust IP6X Anti-water: IPX7 Spring clip strong: 8 tim
[Related Keywords : Overhead Line, Short Circuit Fault Indicator, Earth Fault Indicator, Remote Type]
Business Type
Manufacturer
Location
Guangdong, China
Employees Total
51 - 100
Annual Revenue
USD 500,001 - 1,000,000
Place of origin:
China
Temp. Ambient~250℃ Temp Accuracy ±0.2℃ Dwell Time 0.1~9999s(Heat Seal ) Dwell Time 0.1~9999s(Hot Tack ) Sealing Pressure 0.15MPa~0.7MPa Sealing Jaws 50mmx10mm Teflon Coated Jaws Heating Double Heating Load Cell 200N(Optional:30N50N100N, etc) Accuracy 0.5 F.S. Resolution 0.01N Power 220V, 50 HZ Please contact us, Cell Instruments are professional Hot Tack Tester suppliers.
[Related Keywords : Hot Tack Tester, Tensile Tester]
Business Type
Manufacturer
Location
Shandong, China
Employees Total
101 - 500
Annual Revenue
USD 1,000,001 - 2,000,000
Min. Order:
1 Set
Price:
US$ 7000 ~ 13000
Place of origin:
China
Supply Ability:
1 Set/ Sets per Week
Hot Tack Tester HTT-01 Measures the strength of heat seals formed between thermoplastic surfaces immediately after the seal has been made and before it cools to room temperature. Hot Tack tester is especially important for vertical form-fill-seal packaging. Hot Tack Tester Features Hot tack, heat seal, peeling and tensile test items are integrated in one instrument Sealing jaws are controlled by
[Related Keywords : hot seal strength, heat seal test, sealing machine, hot tack strength]
Business Type
Manufacturer
Location
Shandong, China
Employees Total
11 - 50
Annual Revenue
USD 100,000 - 500,000
Min. Order:
1 Set
Price:
US$ 1 ~ 2
Place of origin:
China
Supply Ability:
999 set per week
is further assessed by analyzing seal continuity through techniques such as air-leak testing, dye penetration, visual examination, or microorganism penetration. Main Parameters Sealing Temp. Ambient~250℃ Temp. Gradient ≤20℃ Deviation ±0.2℃ Sealing Time 0.1S~9999H Sealing Pressure 0.15~0.7 MPa Seal Jaws(mm) U:40*10 5PCS/L:330 1PCS Gas Input 0.7 MPa with Ф6 mm Pipe Power AC 220V 50Hz
[Related Keywords : heat seal tester, plastic film heat seal, packaging heat seal test, ASTM F2029]
Business Type
Manufacturer
Location
Shandong, China
Employees Total
11 - 50
Annual Revenue
USD 100,000 - 500,000
Min. Order:
1 Set
Price:
US$ 1 ~ 2
Place of origin:
China
Supply Ability:
100 sets/month
evaluating seal continuity through methods such as air-leak testing, dye penetration, visual examination, or microorganism penetration, ensuring comprehensive analysis and reliable results. Main Parameters Sealing Temp. Ambient~300℃ Deviation ±0.2℃ Sealing Time 0.1S~9999S Sealing Pressure 0.15~0.7 MPa Seal Jaws 330*10 mm L*W Gas Pressure 0.7 MPa Port Size Ф6 mm PU Hose Power AC 220V 50Hz
[Related Keywords : heat seal tester, heatsealability test, ASTM F2029 heat seal, sealing strength]
Business Type
Manufacturer
Location
Shandong, China
Employees Total
11 - 50
Annual Revenue
USD 100,000 - 500,000
Place of origin:
China
Temperature Integrating Sphere and TMP-8 Multiplex Temperature Tester can fully meet IES LM-82 High Precision LPCE-2(LMS-9000C) System Configuration (It is suitable for the Middle & Small Manufacturer or General Test Lab): High Precision CCD Spectroradiometer (LMS-9000C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050B/LS2050C/LS2012), DC Power Source (DC Series), AC Power Source (LSP-500V
[Related Keywords : LED TESTER]
Business Type
Manufacturer
Location
Shanghai, China
Employees Total
6 - 10
Annual Revenue
USD 100,000 - 500,000
Min. Order:
4000 Set
Price:
US$ 1000
Place of origin:
China
temperature and humidity. A digital hygrometer with a probe is quite a labor-saving and easy to check and manage, which is important in nowadays information age and all are internet of things. TYPES OF HYGROMETER Ht-5d Digital Hygrometer Cp03u Accurate Hygrometer Measuring range: 0.1~99.9%RH; -20~65.9℃ Accuracy: ±2%RH (1%~80%RH); ±0.2℃ (at 25℃) Resolution: 0.1%RH; 0.1℃ Operating Temp.-
[Related Keywords : HYGROMETER]
Business Type
Manufacturer
Location
Jiangsu, China
Employees Total
101 - 500
Annual Revenue
USD 100,000 - 500,000
Min. Order:
1 Carat
Price:
US$ 1000
Place of origin:
China
Temp.-20~70℃ Sensor drift: ≦0.25 (%RH/yr); ≦0.05 (℃/yr) Display Refresh Time: 1 minute Memory: 40,000 measuring values Software: CP03U reader View More Ht-5d Digital Hygrometer Ht-5d Digital Hygrometer Operation Range: 0~50℃, 0~90%RH Precision: ±1.0℃, ±2.0%RH(at 50%RH/25℃) Resolution: 0.1℃, 0.1%RH Dimension: W310xD70xH320mm Weight: 3kgs Power: 110V/230V Visibility Distance: 30m
[Related Keywords : dry box cabinet]
Business Type
Manufacturer
Location
Jiangsu, China
Employees Total
101 - 500
Annual Revenue
USD 100,000 - 500,000
Min. Order:
1 Set
Price:
US$ 6500
Place of origin:
China
Supply Ability:
50 Set/ Sets per Month
Temp.Range: ( RT+10ºC ) ~ 135ºC Free setting (saturated steam temperature). 2. Humidity Range : 100%RH (default value of saturated steam humidity )3. Pressure Range: 0.5Kg/cm2 ~ 3.0Kg/cm2 Absolute pressure; (safe pressure capacity 3Kg/cm2 = 1environmental pressure + 2Kg/cm2 )4. Time Range : 0 ~ 999H / M / S ; optional ; free setting5. Temp. Uniforminity : (+/-)2.0ºC(100ºC)6. Temp. Rising Time
[Related Keywords : HAST, Accelerated Aging Tester]
Business Type
Manufacturer
Location
Guangdong, China
Employees Total
11 - 50
Annual Revenue
USD 100,000 - 500,000
Min. Order:
1 Unit
Price:
US$ 5580
Place of origin:
Indonesia
temp of -70°C with TE Cooling: Negligible dark current without the aggravation or safety concerns associated with LN2• UltraVac™: Critical for sustained vacuum integrity and to maintain unequalled cooling and QE performance, year after year• Single window design: Delivers maximum photon throughput• Front or back illuminated sensor: Offers the best price/performance options• 13 x 13µm
[Related Keywords : Spectometer, ANDOR DV435-BV]
Business Type
Supplier
Location
JAKARTA RAYA, Indonesia
Employees Total
101 - 500
Annual Revenue
USD 50,000,001 - 100,000,000
Min. Order:
50 Unit
Price:
US$ 109.95 ~ 129.95
Place of origin:
Singapore
In the box: Fluke PTi120 Pocket Thermal Camera (9 Hz)Soft caseLanyardUSB cable Specifications: Compact Fluke PTi120 Pocket Thermal Camera Key FeaturesIFOV (spatial resolution)7.6 mRadInfrared resolution120 x 90 (10,800 pixels)Field of view50° H x 38° VDistance to spot130:1Temperature measurement range (not calibrated below -10 °C)-20 °C to 400 °CFocus systemFixed focus, minimum focus distanc
[Related Keywords : Fluke Camera, Thermal Camera, GeoMax, Tester]
Business Type
Supplier
Location
Singapore, Singapore
Employees Total
1 - 5
Annual Revenue
USD 1,000,001 - 2,000,000
Min. Order:
1 Set
Price:
US$ 6000
Place of origin:
China
can be incorporated for additional functionality. 12.(Optional) The inclusion of an RS 232 port and professional software provides further versatility. Main Parameter Test Range 0~1MPa Resolution 0.01KPa Shaking Speed Adjustable Piercing Speed 5mm/s (other available) Sample Height ≤ 350mm (other available) Temp. range 0 ~ 30 ℃ Shaking time 40s (other available) Resolution 0.1 ℃
[Related Keywords : Carbon Dioxide Volume, CO2 content dedetection, carbonated drinks test]
Business Type
Manufacturer
Location
Shandong, China
Employees Total
6 - 10
Annual Revenue
USD 100,000 - 500,000
Place of origin:
China
Price Condition:
FOB
Detailed information: This product is made of imported stainless steel as liner. Shell made of high quality board electrostatic spray. Heating oil pipe in the middle, heating fast,high thermal efficiency, power saving, electronic cosntant temperature. We also switched the control system of the product,whether digital or table display, all eqipped the temperature control device. Oil bath shel
[Related Keywords : Heating Oil Bath, Oil Bath, Laboratory Instrument, Laboratory Water Bath]
Business Type
Manufacturer
Location
Shaanxi, China
Employees Total
11 - 50
Annual Revenue
USD 100,000 - 500,000
Competitive temp. products from various temp. manufacturers and temp. suppliers are listed above, please select quality and cheap items for you.
![]() |
Recommended Content