(1-14 out of 14)

Relay Output DC24V Combustible Gas Detector Gas Alarm

Relay Output DC24V Combustible Gas Detector Gas Alarm
Specifications/Special Features Detect all sorts of combustible gases, natural gas (methane), bottled gas (propane), LPG (Liquefied petroleum Gas), LNG (Liquefied natural gas), coal gas, including ...

Fire Alarm Manual Call Point Adressable Breakglass

Fire Alarm  Manual Call Point Adressable Breakglass
Instruction manual of C-6004 manual call point A. Features 1.Built-in product ID code 2. Using hardware and software filtering to improve the anti-interference ability of the manual call point ...

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel
Specifications 2.4.1 Power Supply: AC power: Nominal operation voltage 220VAC (187VAC ~ 242VAC) Standby Battery: 2 x 12V/12AH 2.4.2 Operating Environment: Temperature: 0℃~+40℃ Relative ...

2-wire DC24V Sound Strobe Fire Sound Light

2-wire DC24V Sound Strobe Fire Sound Light
General The Sound Strobe of notification appliances offers a wide range of Sound/strobes, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC ...

Open Flame Detector 2/4-Wire UV Flame Detector with Relay Output

Open Flame Detector 2/4-Wire UV Flame Detector with Relay Output
Specifications/Special Features Operating Voltage Range: 12 to 30 VDC Volts Standby Current: ≤10 mA 24 VDC Alarm Current ≤30 mA 24 VDC Spectrum: 180~290nm Detection Angle: 110 degree Detection ...

Conventional Fire Alarm Control Panel Fire Alarm System

Conventional Fire Alarm Control Panel Fire Alarm System
General Conventional Fire Alarm Control Panel with four Zones Key Specifications/Special Features Four Style B (Class B) Initiating Device Circuits (IDCs). All zones accept two-wire smoke detectors ...

Smoke Detector Adressable Fire Alarm Wire Smoke Alarm

Smoke Detector Adressable Fire Alarm Wire Smoke Alarm
Specifications 1.Working voltage:15-28V Impulse voltage 2.Working current: 1)Standby current:≤0.5mA 2)Alarm current:≤2.8mA 3.Type:Addressable, 2 wire(nonpolarity) 4.Encoding: Electronic ...

Addressable Smoke Detector for Addressable Fire Alarm System

Addressable Smoke Detector for Addressable Fire Alarm System
Specifications 1.Working voltage:15-28V Impulse voltage 2.Working current: 1)Standby current:≤0.5mA 2)Alarm current:≤2.8mA 3.Type:Addressable, 2 wire(nonpolarity) 4.Encoding: Electronic ...

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel
Specifications 2.4.1 Power Supply: AC power: Nominal operation voltage 220VAC (187VAC ~ 242VAC) Standby Battery: 2 x 12V/12AH 2.4.2 Operating Environment: Temperature: 0℃~+40℃ Relative ...

EN14604 Certification High Sensitivity Smoke Detector Convenient Fire Detector,Fire Alarm

EN14604 Certification High Sensitivity Smoke Detector  Convenient Fire Detector,Fire Alarm
Battery Powered Photoelectric Smoke Alarm with excellent stability and high-sensitivity. Key Specifications/Special Features Power Source: 9V Battery (included). Audio Alarm: ≥ 85dB/3m Temperature ...

Home and hotel AC Power220V Standalone Smoke Alarm smoke detector , 9V battery Backup

Home and hotel AC Power220V Standalone Smoke Alarm smoke detector , 9V battery  Backup
Powered Photoelectric Smoke Alarm with excellent stability and high-sensitivity. Key Specifications/Special Features Power Source: 90VAC~ 270VAC, Battery backup (included). Audio Alarm: ≥ ...

Standalone Photoelectric 9V Battery Backup Smoke Detector ,Smoke Alarm ,Fire Detector

Standalone Photoelectric 9V Battery Backup Smoke Detector ,Smoke Alarm ,Fire Detector
Smoke Alarm with excellent stability and high-sensitivity . Key Specifications/Special Features Power Source: 9V Battery (included). Audio Alarm: ≥ 85dB/3m Temperature Range: 0℃ to ...

Conventional Fire Alarm Control Panel Smoke Alarm Systems

Conventional Fire Alarm Control Panel Smoke Alarm Systems
Conventional Fire Alarm Control Panel with four Zones Key Specifications/Special Features Four Style B (Class B) Initiating Device Circuits (IDCs). All zones accept two-wire smoke detectors and any ...

Firre Alarm Supplier Standalone Photoelectric Fire Smoke Detector with CE and RoHS

Firre Alarm Supplier Standalone Photoelectric Fire Smoke Detector with CE and RoHS
Specifications Operating Voltage 2*1.5V AA batteries Standby Current ≤ 8 uA Maximum Alarm Current ≤ 50mA Operating Humidity Range 10% to 93% Relative Humidity,Non-condensing Operating ...
Page 1 of 11
Go to Page Go

Browse: Manufacturer Directory Premium Suppliers Site Map

About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838

Inquiry Basket ()