There are 1 8zones control panel from 1 suppliers on EC21.com
Related Searches : control panel , fire alarm control panel , fire alarm , fire alarm panel , fire control
Price
Supplier Info.
Report Item
Your report on Product(s) will be sent to EC21 Administrators once submitted.
Then, Administrators will investigate and then take appropriate actions.
Contact Supplier
|
Skype firealarm87 /wechat 15220176087 Conventional Fire Alarm Control Panel with eight Zones |
The PANEL is a 4-zone to 16-zone FACP (Fire Alarm Control Panel), which uses conventional input devices. The panel accepts water flow devices, two-wire smoke detectors, four-wire smoke detectors, pull stations and other normally-open contact devices. Outputs include four Notification Appliance Circuits (NAC, SOUND1-4), three standard Form-A relays (alarm, trouble and supervisory) and an EIA-485 port to interface with remote annunciators and optional remote relay modules. The FACP is field programmable via the panel keypad. It also supervises all wiring, AC voltage and battery level.
This series of panels are basically the same in application and operation, their differences are shown in Table 1-1. PANEL will be described as the example in the following sections.
Table 1-1
|
FACP |
Number of Detection Zones |
Number of Sounder Outputs |
Output Delay Settings |
|
PANEL-4 |
4 |
1 |
N/A |
|
PANEL-8 |
8 |
2 |
N/A |
|
PANEL-16 |
16 |
4 |
N/A |
1.1 ProductFeatures
l 4,8,16 Class B Initiating Device Circuits (IDCs)
✓ All zones accept conventional detectors and any normally open contact device
l Four Class B Notification Appliance Circuits (NACs)
l One Form-A Alarm Relay
l One Form-A Trouble Relay
l One Form-A Supervisory Relay
l 3.0 amps of system power
l Max 20 conventional detectors in one zone.
l Auto/Manual mode setting enable walk test.
l Each Zone can be disabled,
l Sound output can be disabled.
l Manual active sound output enabled.
l Able to report short and broken circuit of detection zones.
l Designed with standby batteries and space provision for two sealed lead-acid batteries.
l Testing and disable functions.
l Can connect max 32 repeater panels by RS485 communicaiton port
| Registration Date | 2014/03/17(Year/Month/Date) |
|---|---|
| Buyer / Seller in EC21 | Seller |
| Business Type | Agent |
| Year established | 2009 |
| Employees total | 51 - 100 |
| Annual revenue | USD 5,000,001 - 10,000,000 |
| Company | Shenzhen Zoanco Electronics Co.,Ltd. |
|---|---|
| Address | 4f, Building B1, Xinhaosheng High-Tech Park, Yonghe Road, Fuyong Town, Baoan District, Shenzhen, GuaShenzhenGuangdong518103China |
| Phone | +86 - 0755 - 15220176087 |
| Fax | 86 - 755 - 23015236 |
| Contact | Jenny Ning / sales manager |