There are 722 PANEL METER from 399 suppliers on EC21.com
Related Searches : transformer , inverter , connector , meter , power transformer , electrical , transformers , cable
Supplier Info.
Report Item
Your report on Product(s) will be sent to EC21 Administrators once submitted.
Then, Administrators will investigate and then take appropriate actions.
Contact Supplier
- Measuring RMS
- Multi input range
- Wide display range
- 4rows (-1999~9999), 5rows (19999~99999)
| Model | MP3-A | MP3-B | MP6-A | MP6-B | ||||
| Appearance |
|
|
|
|
||||
| 96(W) x 48(H) x 100(D) | 72(W) x 36(H) x 100(D) | |||||||
| Power Supply | 100 ~ 240 V AC 50 - 60Hz allowable operating voltage range : 85 ~ 110 % | |||||||
| Power Consumption | 7 VA | |||||||
| Display | 7 segment LED Display | |||||||
| Insulation Resistance | 100 MΩ min. (at 500 V DC) between external terminal and case | |||||||
| Dielectric Strength | 2000 V AC min. for 1 minute between external terminal and case | |||||||
| Noise Immunity | By noise simulator, square-shaped wave noise, pulse width 1 µs , ± 1000 V | |||||||
| Vibration Resistance | Malfunction : 10 ~ 55 Hz Single amplitude 0.5 mm X•Y•Z each direction for 1 hour | |||||||
| Durability : 10 ~ 55 Hz Single amplitude 0.75 mm X•Y•Z each direction for 2 hours | ||||||||
| Shock Resistance | Malfunction : 100 m/s2 for 3 times each in X•Y•Z direction | |||||||
| Durability : 300 m/s2 for 3 times each in X•Y•Z direction | ||||||||
| Operating Ambient temperature | -10 ~ +55 °C (with no freezing) | |||||||
| Operating Ambient Humidity | Relative Humidity 35 ~ 85 % RH | |||||||
| Operating Circumstance | With no corrosive gas | |||||||
| Storage Ambient Temperature | -20 ~ 65 °C (with no freezing) | |||||||
| Relay Life Expectancy |
|
|||||||
| Net Weight | Approx. 180 g | |||||||
| Model | Suffix Code | Description | ||||
| MP | ||||||
| Aspect Dimension | 3 | Aspect 96 x 48 mm | ||||
| 6 | Aspect 72 x 36 mm | |||||
| Displayable Digits | 4 | 4 digits (9999) | ||||
| 5 | 25 | 5 digits (99999) | ||||
| Measurement Input Specification | DV | d.c VOLT | ||||
| DA | d.c AMPERE | |||||
| AV | a.c VOLT | |||||
| AA | a.c AMPERE | |||||
| AVR | a.c VOLT(RMS) | |||||
| AAR | a.c AMPERE(RMS) | |||||
| Output Specification (Option) | N | Display only | ||||
| 0 | Relay Output(HI,GO,LO) + Current Output(4~20 mA) | |||||
| 1 | Relay Output (HI, GO, LO) | |||||
| 2 | NPN Open Collector Output(HI,GO,LO), BCD Output(Static) | |||||
| 3 | PNP Open Collector Output(HI,GO,LO), BCD Output(Static) | |||||
| 4 | NPN Open Collector Output(HI,GO,LO), Current Output(4~20 mA) | |||||
| 5 | PNP Open Collector Output(HI,GO,LO), Current Output(4~20 mA) | |||||
| 6 | NPN Open Collector Output(HI,GO,LO), Serial Output(low speed) | |||||
| 7 | PNP Open Collector Output(HI,GO,LO), Serial Output(low speed) | |||||
| 8 | NPN Open Collector Output(HI,GO,LO), RS485 Output | |||||
| 9 | PNP Open Collector Output(HI,GO,LO), RS485 Output | |||||
| Type | A | Acrylic type | ||||
| B | Table type | |||||
| * | Current Output about PV (present value) |
| * | Output Specification, 0 ~ 9, is “OPTION.” |
| * | The specification of this manual may be changed without a prior notification due to its improvement |
| * | When measuring a current higher than DC 5 A, an exclusive shunt will be necessary so please choose |
| “Type of DC Volt” when you are ordering. |
| Registration Date | 2005/01/22(Year/Month/Date) |
|---|---|
| Buyer / Seller in EC21 | Seller |
| Business Type | Manufacturer |
| Year established | 1972 |
| Employees total | 101 - 500 |
| Annual revenue | USD 500,001 - 1,000,000 |
| Company | Hanyoung Nux Co., Ltd |
|---|---|
| Address | #1381-3, Juan 5-dongNam-guIncheonKorea |
| Phone | 82 - 32 - 8707735 |
| Fax | 82 - 32 - 8764696 |
| Homepage | http://www.hynux.net |
| Contact | ALLEN OH / Manager |