There are 4 Definite Purpose Contactors from 1 suppliers on EC21.com
Related Searches : air conditioner , air conditioning , air conditioners , air cooler , thermostat , air condition
Supplier Info.
Report Item
Your report on Product(s) will be sent to EC21 Administrators once submitted.
Then, Administrators will investigate and then take appropriate actions.
Contact Supplier
specifications: 1) Name: 1 pole definite purpose contactor 2) Model number: HLC-1X 3) Contact: a) Arrangements: 1 pole X with shunt b) Structure: double make contacts c) Materials: silver cadmium oxide (10% 30Amp, 13% 40Amp) d) Max. loading rating: see contact rating chart 4) Coil: a) Coil voltage: 50 / 60Hz (see coil rating chart) b) Nominal resistance: see coil rating chart c) Nominal inrush power: 5VA 60Hz, 6VA 50Hz d) Coil temperature rise: 65oC (max.) e) Class of insulation: 130oC class B 5) Operation: a) Must operate voltage: 85% of nominal coil voltage or less (24V AC=75% or less) b) Must release voltage: 10% - 60% of operating voltage c) Initial operating time: 20ms typical d) Initial release time: 10ms typical e) Bounce time: 0 to 10 ms typical 6) Environment: a) Temperature range (storage and operation): -40 ~ 65oC 7) Initial dielectric strength: a) Between contacts and coil: 2,500V AC b) Between poles: 2,500V AC c) Between open contacts: 2,500V AC 8) Mechanical data (power pole termination: wire size, tightening torque): a) #10-32 screw: 16 - 8 AWG, 22Ibf. -in.(2.49Nm) b) Box lug: 14 - 4 AWG, 40Ibf. -in. (4.52 Nm) 9) Coil termination: dual 0.250 quick connects (6.35mm) 10) Unit weight without optional cover: 7oz. (200g) 11) Life expectancy: depends upon duty cycle, load and environmental conditionals 12) Mechanical life: a) Design requirement AR1780 = 500,000 operations b) Minimum test requirement = 1,000,000 operations at 60 operations per minute, 50% duty cycle, 150F and 110% of nominal coil voltage 13) Electrical life test results: a) 40 and 50 RLA (resistive load) b) 250,000 operations make, carry and break 100% pf. 600V AC 30 FLA rated c) 200,000 operations make LRA 40 - 50% pf., break 125% FLA 75 to 80% pf. 240V AC d) 250,000 operations make, carry, break 75 - 80% pf. 240V AC e) 250,000 operations make, carry, break 75 -o 80% pf. 600V AC 40 FLA rated f) 100,000 operations make LRA 40 - 50% pf., break 125% FLA 75 - 80% pf. 240V AC g) 250,000 operations make, carry, break 75 - 80%pf. 240V AC h) 300,000 operations make, carry, break 75 - 80%pf. 600V AC
| Registration Date | 2004/11/02(Year/Month/Date) |
|---|---|
| Buyer / Seller in EC21 | Both |
| Business Type | Manufacturer |
| Year established | 1996 |
| Employees total | 101 - 500 |
| Annual revenue | USD 2,000,001 - 5,000,000 |
| Company | ZHEJIANG HONGLI ELECTRIC CO.,LTD |
|---|---|
| Address | SONGHU INDUSTRIAL ZONE YUEQINGWenzhouZhejiang325600China |
| Phone | +86 - 577 - 62526555 |
| Fax | 86 - 577 - 62526536 |
| Homepage | http://www.hongli.com.cn |
| Contact | LIQIAN WANG / GENERAL MANAGER |