NIBP Module Model NB001, Small, simple, excellent reliability and ease of installation clinical monitoring of the accuracy with the latest digital signal processing technology to achieve anti-noise and software algorithms anti-interference by moving arm, capable of accomplishing all NIBP measurement items, comply with CE safety design, ...
Characteristics:
Small in size, simple, excellent reliability and ease of installation clinical monitoring of the accuracy
The latest digital signal processing technology to achieve anti-noise and software algorithms anti-interference by moving arm
Capable of accomplishing all NIBP measurement items
comply with CE safety design
Comply with all NIBP standard of ANSI/AAMI
Applies to adults, children and Newborn
5V/12V single powersupply to avoid interference with the digital circuit by the pump
Fully compatible with the protocol of CAS Non-invasive blood pressure module (NIBP)
Performance indicators:
Measuring range
Adult:
30 ~ 255 mmHg systolic blood pressure
An average of 20 ~ 235 mmHg pressure
15 ~ 220 mmHg diastolic blood pressure
Pulse rate of 30 ~ 240 times / min
Newborn:
30 ~ 135 mmHg systolic blood pressure
An average of 20 ~ 125 mmHg pressure
15 ~ 110 mmHg diastolic blood pressure
Pulse Rate of 40 ~ 240 times / min
Measurement time
Adults: up to more than 120 seconds;
Newborn: up to more than 90 seconds;
Restrictions on over-voltage software
Adult: Less than 290mmHg;
Newborns: no more than 145mmHg;
Hardware over-voltage protection
Adult: 300 ± 10 mmHg;
Newborn: 150 ± 4 mmHg;
Measuring principle: Oscillometry
Deflation approach: ladder Deflated
The initial inflation pressure value
Adult: 150 mmHg;
Newborn: 70 mmHg;
Sensor zero reset: Prior to each measurement
Resolution: 1 mmHg
Measurement accuracy
Maximum average deviation: no more than ± 5 mmHg;
maximum standard deviationï¼Â less than 8 mmHg;
Pressure accuracy instructions: ± 3 mmHg
Leakage: less than 6 mmHg Per minute;
Electrical performance
Voltage: 12 VDC (adapt to the corresponding valve), 5 VDC
Quiescent current: 80 mA
Measurement current: 200 mA
inflated current: 600mA
Environment
Operating Temperature: 0 ~ 55 Celsius degrees
Storage Temperature: -20 ~ 65 Celsius degrees
Humidity Range: 0 ~ 95%, non-condenser
Operation Altitude: -500 m ~ 4600 meters
Life Span: can operate 100,000 blood pressure measurements
Size: 12.6 cm x 6.8 cm x 2.8 cm
Weight: 180 g
Function
1. Numerical calculation: calculate systolic blood pressure, mean pressure, diastolic blood pressure, pulse rate.
2. Automatic measurement mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90 minutes.
3. Manual measurement mode: the user needed to manually start a measurement.
4. Calibration mode: the value of continuity in the provision of cuff pressure
5. Measurement unit: mmHg
6. Serial Communication: RS232 port, TTL-level, 4800 baud rate
7. Self checking: selfchecking function available after reset
| NIBP Module MONM-NB001, Small, simple, excellent reliability and ease of installation clinical monitoring of the accuracy with the latest digital signal processing technology to achieve anti-noise and software algorithms anti-interference by moving arm, capable of accomplishing all NIBP measurement items, comply with CE safety design, ... |
There are no documents download yet.
| Registration Date | 2009/05/09(Year/Month/Date) |
|---|---|
| Buyer / Seller in EC21 | Seller |
| Business Type | Trading Company |
| Year established | 2003 |
| Employees total | 6 - 10 |
| Annual revenue | USD 100,000 - 500,000 |
| Company | Goldwei Corporation |
|---|---|
| Address | 2595 James Madison CircleHerndonVirginia20171United States |
| Phone | 1 - 703 - 7130198 |
| Fax | 1 - 320 - 5140198 |
| Contact | John wei |