There are 3362 monitoring system from 1471 suppliers on EC21.com
Related Searches : transformer , inverter , connector , meter , power transformer , electrical , transformers , cable
Supplier Info.

Report Item
Your report on Product(s) will be sent to EC21 Administrators once submitted.
Then, Administrators will investigate and then take appropriate actions.
Contact Supplier
It's an automation system which uses PC in controlling and managing a factory or a building. PC MONITORING, in application of 3D graphic and animation, exercises its control and management in virtual reality while various communication methods and real time TREND function are provided.
During the past, supervision over devices spreaded out in fields called for the supervisor's presence at the site to watch them personally, but now through this monitoring system they can be controlled directly or indirectly simply by watching computer screen.
This kind of cutting edge system, besides its contribution of general information as like run/stop, operation alarming and etc, does not stop short of informing detailed operating conditions inside the devices to the administer's understanding, which actually benefits to saving manpower and effective maintenance and repair.
Further, if devices in operation alert an alarming as set up, the alarm-relay function will work to alert it to the administer's mobile phone inviting prompt measures thereby.
Features of PC Monitoring System
![]() |
-3 dimension graphic supervision 3 dimension graphic and animation are applied to controlling devices' conditions in order for users to easily understand the monitoring screen. Devices' conditions as represented by 3D Graphic are easy for users to understand while the devices' inner sights are presented in virtual reality including inside-situations thereby. Virtual reality in the control is possible to come by as processes or events like living things are accompanied by the graphic elements of 3D Graphic and animation. |
![]() |
-Realtime and Historical TREND Supervision program basically includes TREND function which, through simple manipulation, stores and shows data, and statistics is available from analogue/digital data summed up by minute. TREND function keeps on storing analogue and digital data as per minutes, and view data is available by 1/8/24/48/72 hours and 30 days, and by minute/hour/day/week/month. |
![]() |
-Paging Through the paging function, the administrator out of place can be informed of alarms, enabling prompt measures thereby. |
![]() |
-Print Report Any and all the operation data can be printed to report at a designated time. Every type of report printing is possible and momentary alarming print or designated-time print is possible. Print Report works for documentations of device management, and each history for each device can be managed. Editing of some parts or elements as needed by user as well as comprehensive statistics are possibly done by report management. |
Expected effects of PC monitoring system
-Convenient management
Convenient management and reducing number of concerned workers by the centralization of supervision, in service of high resolution and 3 dimension, over many devices' running conditions to one point from numerous spreaded-out places.
- Artificial Intelligence
MICOM is connected to exiting devices in order to communicate with computer, and the computing will be done at DDC by and through digitalized precision control, optimum start/stop control, load weight control, compressor operation according to the schedule program, which results in energy saving and extension of devices' durability.
-Enhancement of job efficiency
Variables such as devices' pressure condition or temperature are continually prepared by each time and printed out in a report form in an aid to enhancement of job efficiency.
-Easy-going maintenance and repair
As the things like total running time by each unit, numbers of ON/OFF, alarming time and details thereof, actions to alarms and etc are confirmed in the central computer, it is convenient for administrators to do managements and make prompt actions to alarms
-Data keeping and analysis
It is easy-going with past-data-keeping and estimated-data-trend analysis, and devices' variables are noted in trend graph informative of the most optimization of devices' running.
System configuration

Network configuration

Monitoring Screen Overseeing the whole

Supervisory screen on constant temperature&humidity provider

Applied area of PC monitoring system
![]() |
-Air conditioning control This system controlling temperature/humidity of an entire building covers air conditioning facilities such as boiler, cooling tower, humidifier, cooler etc while DDC takes charge of operation for each area and PC reissues its commands to the related area after determination on temperature/humidity necessary for operation. Screen displays for building's air conditioners and constant temperature/humidity providers can be made individually as well as comprehensively in total, and images resembling actual air conditioners as being adopted enables effective controlling as if looking at actual shapes of devices. |
![]() |
- Illumination control Illumination control system aiming at controlling over illuminations of the entire building Illumination control system supervises and controls over respective illuminations of the entire building. Controlling over each floor is provided individually as per operations by areas, and, on the basis of individual control over each illumination, controlling over rooms group by group can be done while scheduled automatic controlling will be helpful for saving energy. |
![]() |
- Water supply/drainage(wastewater) control |
![]() |
-Remote supervision System controlling spontaneously over multiple sites as spreaded out through telephone or network. While the system supervises and controls over remote sites through telephone or network, the remote supervision 24 hours a day is possible as similar as such that is performed within a building. |
| Registration Date | 1999/10/14(Year/Month/Date) |
|---|---|
| Buyer / Seller in EC21 | Seller |
| Business Type | Manufacturer |
| Year established | 1987 |
| Employees total | 11 - 50 |
| Annual revenue | USD 2,000,001 - 5,000,000 |
| Company | Seungil Electronics |
|---|---|
| Address | 16-8, Dodang-dong, Wonmi-gu, Bucheon,Gyeonggi-do422-020Korea |
| Phone | 82 - 32 - 6822380 |
| Fax | 82 - 32 - 6822383 |
| Homepage | http://www.si-tec.co.kr |
| Contact | Sangjin Byun / Assistant Manager |