Surge protective devices (SPDs) are designed to meet requirements for UL 1449 Forth Edition and IEC/EN 61643-11. They are DIN-rail mountable featuring a fail-safe protection, visual indicator and...
Surge protective device module (SPD-M) is an onboard lightning protection module that integrates functions, such as thermal protection, overvoltage protection, and remote signaling, and others. A...
Patent product. Plug-in metal oxide surge arrester is also called over-voltage protection which is designed for mainly protecting CGIS facilities below 52kV. Used for protection of metal-enclosed...
This specification applies to 1-4.2 kV metal-oxide surge arresters used to protect against lightning and switching overvoltage the input circuits of the locomotive. The surge arresters are of the...
This specification applies to 4.5 kV metal-oxide surge arresters used to protect against lightning and switching overvoltage the input circuits of the locomotive. The surge arresters are of the...
A disconnector is incorporated in the type WDLB outdoor a.c. high-voltage drop-out MOA ,and it will actuate before the MOA is damaged. So MOA will drops out quickly and terminates its operation, and...
AMTECH produces wide range of surge arrester in large scale, either with porcelain or polymeric housing, metal-claded and gas-insulated, or for specific application in high altitudes or heavily...
Product DescriptionCombined AC SPD Type 1 and Type 2 Lightning Current Arrester and Surge Arrester GENERAL INFORMATION●Varistor surge protective device (AC SPD)●Combined SPD Type 1&2 with MOV and...
Product DescriptionThe ENOCH 15KV 200A Elbow Arrester 17/45 combines metal oxide varistor module in a rubber elbow toprovide overvoltage system protection. The ENOCH arrester elbow housing design...
Arresters: Distribution & Station Class Polymer Cut Out Switch Polymer Surge Absorbers Polymer Insulators for Railway Please feel free to contact D.M Kim or Joo Lee for any inquiry & further...
arrester is malfunctioning, the disconnector will be activated and cut off the connection with transmission line automatically, thus ensures the continuous power supply. The system’s...
Insulation Polymer Housing Without Interruption MOA Due to whole-forming for wire of high voltage terminal and core of MOA, the fully Insulated Polymer Housed MOA has the features of simple structure...
Three-phases-in-one combination polymeric housed MOA is designed for protecting 35kV (or lower) neutral-point non-earthing electrical equipments from damage due to over-voltage. Because of the...
A disconnector must work when there is faulty current. According to the national standard GB11032, dynamic ampere-second characteristic is to be tested at power frequency current 800A, 200A, 20A, 5A...