Search Advanced Search
Products > technic parameter > Hangzhou Yanei Intelligent Control Technology Co., Ltd. | Similar Products
Your search for "

technic parameter

" found 15 Products from Hangzhou Yanei Intelligent Control Technology Co., Ltd., China

(1-15 out of 15)

DG13-D Plus Water-reactive Gas Release Test Apparatus

DG13-D Plus Water-reactive Gas Release Test Apparatus
Technical parameters 1. Working environment: -5℃ to 45℃, <95% RH; 2. Gas volume measurement accuracy: ±1mL, resolution: 0.01mL; 3. Gas release rate detection range: 0~36L/min; 4. Gas collection ...

DG13-D Water-reactive Gas Release Test Apparatus

DG13-D Water-reactive Gas Release Test Apparatus
Technical parameters 1. Working environment: -5℃ to 45℃, <95% RH; 2. Gas volume measurement accuracy: ±1.5mL, resolution: 0.01mL; 3. Gas release rate detection range: 0~36L/min; 4. Gas ...

DG12-D Self-ignition Liquid Test Apparatus

DG12-D Self-ignition Liquid Test Apparatus
Technical parameters 1. Working environment: -5℃ to 45℃, <95% RH; 1. 计时范围:0~999s,计时精度:±0.01s; 2. Timing range: 0-999s, timing accuracy: ±0.01s; 3. Reaction vessel: Industrial white porcelain, ...

DG11-D Self-ignition Solid Test Apparatus

DG11-D Self-ignition Solid Test Apparatus
Purpose and standards 1. This apparatus is used to determine whether solid substances burn in contact with air. 2. The self-ignition solid test apparatus complies with the following standards: u ...

DG10-D Plus Solid Combustion Rate Test Apparatus (Image Method)

DG10-D Plus Solid Combustion Rate Test Apparatus (Image Method)
Technical parameters 1. Working environment: -5℃ to 45℃, <95% RH; 2. Combustion distance detection range: 0-250mm, accuracy: ±0.5mm; 3. Combustion rate detection range: 0-500m/s; 4. Timing ...

DG10-D Solid Combustion Rate Test Apparatus

DG10-D Solid Combustion Rate Test Apparatus
Technical parameters 1. Working environment: -5℃ to 45℃, <95% RH; 2. Combustion distance detection range: 0-250mm, accuracy: ±0.5mm; 3. Combustion rate detection range: 0-500m/s; 4. Timing ...

DG09-D Liquid Sustained Combustion Test Apparatus

DG09-D Liquid Sustained Combustion Test Apparatus
Technical parameters 1. Working environment: -5℃ to 45℃, <95% RH; 2. Atmospheric pressure measurement range: 0-110kPa, accuracy: ±0.25% F·S; 3. Temperature control range: Room temperature +5 to ...

DG08-D Foam Aerosol Flammability Test Apparatus

DG08-D Foam Aerosol Flammability Test Apparatus
Technical parameters 1. Working environment: -5℃ to 45℃, <95% RH; 2. Flame height detection range: 0-330mm; 3. Flame height detection accuracy: ±0.5mm; 4. Flame height detection resolution: ...

DG07-D Aerosol Spray Enclosed Space Test Apparatus

DG07-D Aerosol Spray Enclosed Space Test Apparatus
Technical parameters 1. Working environment: -5℃ to 45℃, <95% RH; 2. Cylindrical container dimensions: Volume of 200dm³, diameter of 600mm, and length of 720mm; 3. Adjustable distance between ...

DG06-D Aerosol Spray Ignition Distance Test Apparatus

DG06-D Aerosol Spray Ignition Distance Test Apparatus
Technical parameters 1. Working environment: -5℃ to 45℃, <95% RH; 2. Spectral response range: Ultraviolet band: 185-260nm, infrared band: 760-1100nm, spectral response frequency: 5000Hz; 3. ...

DG05-D Self-Heating Substance/75C Thermal Stability Test Apparatus

DG05-D Self-Heating Substance/75C Thermal Stability Test Apparatus
Technical parameters 1. Working environment: -5℃ to 45℃, <95% RH; 2. Oven temperature control range: Room temperature to 200℃; 3. Temperature accuracy: ≤±1℃, temperature fluctuation: ≤±0.5℃; 4. ...

DG04-D BAM Friction Sensitivity Test Apparatus

DG04-D BAM Friction Sensitivity Test Apparatus
Technical parameters 1. Working environment: -5℃ to 45℃, <95% RH; 2. Motor speed: 140±3rpm (maximum load); 3. Distance between weight and ceramic rod center: 11cm, 16cm, 21cm, 26cm, 31cm, ...

DG03-D Impact Sensitivity Test Apparatus

DG03-D Impact Sensitivity Test Apparatus
Technical parameters 1. Working environment: -5℃ to 45℃, <95% RH; 2. Impact load range: 0.5, 1, 2, 5 and 10 kg (customizable according to customer needs); 3. Maximum drop height: 1000mm ...

DG02-D Oxidizing Liquid/Time-Pressure Test Apparatus

DG02-D Oxidizing Liquid/Time-Pressure Test Apparatus
Technical parameters 1. Working environment: -5℃ to 45℃, <95% RH; 2. Pressure vessel: Cylindrical stainless steel pressure vessel with a length of 89mm, outer diameter of 60mm, and side-mounted ...

DG01-D Koenen Test Apparatus

DG01-D Koenen Test Apparatus
Technical parameters 1. Working environment: -5℃ to 45℃, <95% RH; 2. Heating method: Propane gas heating; 3. Propane flow adjustment range: 0 to 10,000 sccm; 4. Propane adjustment response speed: ...
Page 1 of 11
Go to Page Go

Browse: Manufacturer Directory Premium Suppliers Site Map

About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838